Logic
Definition
Default
Cross
out
setting
used
Optional extras
IBL OPEN
Block pulses
during opening
0
0
Pulse from inputs configured as Start E, Start I, Ped has effect during opening.
1
Pulse from inputs configured as Start E, Start I, Ped has no effect during opening.
ice
Ice feature
1
0
The Amperostop safety trip threshold stays at the same set value.
1
The controller automatically adjusts the obstacle alarm trip threshold at each start up.
Check that the force of impact measured at the points provided for by standard EN 12445 is lower than the value
laid down by standard EN 12453. If in doubt, use auxiliary safety devices.
This feature is useful when dealing with installations running at low temperatures.
WARNING: once this feature has been activated, you will need to perform an autoset opening and closing cycle.
OPEN IN OTHER
DIRECT.
Open in other
direction
0
Standard operating mode (
See Fig.M)
.
1
Opens in other direction to standard operating mode (
See Fig. M
)
SAFE 1
Configuration
of safety input
SAFE 1.
72
6
0
Input configured as Phot (photocell).
1
Input configured as Phot test (tested photocell).
2
Input configured as Phot op (photocell active during opening only).
3
Input configured as Phot op test (tested photocell active during opening only).
SAFE 2
Configuration
of safety input
SAFE 2.
73
4
4
Input configured as Phot cl (photocell active during closing only).
5
Input configured as Phot cl test (tested photocell active during closing only).
6
Input configured as Bar, safety edge.
7
Input configured as Bar, tested safety edge.
8
Input configured as Bar 8k2.
(Inactive on SAFE 2).
9
Input configured as Bar OP, safety edge with inversion active only while opening. If while closing, the movement stops.
10
Input configured as Bar OP TEST, safety edge tested with inversion active only while opening. If while closing, the
movement stops.
11
Input configured as Bar OP 8k2, safety edge with inversion active only while opening. If while closing, the movement
stops.
(Inactive on SAFE 2).
12
Input configured as Bar CL, safety edge with inversion active only while closing. If while opening, the movement stops.
13
Input configured as Bar CL TEST, safety edge tested with inversion active only while closing. If while opening, the
movement stops.
14
Input configured as Bar CL 8k2, safety edge with inversion active only while closing. If while opening, the movement
stops.
(Inactive on SAFE 2).
15
Not used
16
Input configured as STAR 8k2.
(Inactive on SAFE 2).
IC 1
Configuration of
command input
IC 1.
61
0
0
Input configured as Start E.
1
Input configured as Start I.
2
Input configured as Open.
3
Input configured as Close.
IC 2
Configuration of
command input
IC 2.
62
4
4
Input configured as Ped.
5
Input configured as Timer.
6
Input configured as Timer Pedestrian.
1ch
Configuration
of the 1st radio
channel com-
mand
0
0
Radio control configured as START E.
1
Radio control configured as Start I.
2
Radio control configured as Open.
2ch
Configuration
of the 2nd
radio channel
command
4
3
Radio control configured as Close
4
Radio control configured as Ped
5
Radio control configured as STOP
3 ch
Configuration
of the 3rd radio
channel com-
mand
9
6
Not used
7
Not used
8
Not used
4 ch
Configuration
of the 4th radio
channel com-
mand
5
9
Radio control configured as AUX3 **
10
Radio control configured as EXPO1 **
11
Radio control configured as EXPO2 **
12
Not used
AUX 3
Configuration of
AUX 3 output.
26-37
0
0
Output configured as monostable Radio Channel.
1
Output configured as SCA (gate open light).
2
Not used
3
Output configured as ZONE LIGHT
4
Output configured as STAIR LIGHT
5
Not used
6
Output configured as FLASHING LIGHT
7
Not used
8
Not used
9
Output configured as Maintenance
10
Output configured as FLASHING LIGHT AND MAINTENANCE
11
Not used
12
Not used
13
Output configured as closed Gate Status
14
Output configured as Bistable Radio Channel
15
Output configured as timed Radio Channel
16
Output configured as open Gate Status
ENGLISH
HIDE SL SMART BT A150-A300
-
37
D813983 0AA65_01
Summary of Contents for HIDE SL SMART BT A150
Page 68: ...www bftme ae ...