background image

P a g e

 | 

33

 

Change History 

Key: 

 

P = Panel version    H = Hardware PCB version     S = Software version 
 

Version 

Reason for change 

Date 

4 hour reboot software. New filter board. 24v dc PSU. 

Oct 2018 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 

 
 
 

Warranty Terms 

Please note, by installing this product, you are accepting the following warranty terms: 

 

1. The manufacturer’s warranty is a “return to base” 2 year warranty from date of manufacture. This means that 
any suspected defective components or items are returned to the manufacturer

’s agent (

BFT Americas Inc

) for 

investigation and diagnosis, and returned at the cost of the customer. 
2. The warranty does not cover, nor is the manufacturer or agent responsible for any of the following 
whatsoever: Storm damage, lightning or surge damage, flooding, accidental damage, vandalism or deliberate 
damage, un-explained corrosion or unusually harsh environments, failure of telephone networks, future un-
interoperability between the product and network providers which cause mal-function due to changes 
implemented by the phone providers after manufacture of the product, or that which is outside of control of the 
manufacturer (e.g. 2G, 3G switch off, removal or inability to obtain VOLTE service), and damage due to not 
proper installation. 
3. The manufacture in no way accepts liability for any of the following incurred due to a product defect: Cost of 
attending site, inconveniences, labour rates, time lost, loss to or damage to property, security breaches, late 
payment clauses or breaches of any contracts between the installer and the client. 
4. This is a profession install product only. The product is a component of an overall system. Therefore, it is the 
responsibility of the installer to certify the safety and compliance of the overall finished system. As soon as this 
product is fixed to another item, or connected to another third-party device, then the product has been modified, 
and compliance with local regulations in the country of install is strictly the responsibility of the installer. 
5. Re-stocking fees may apply to items returned that are found to be non-defective. Complete units will also 
attract a re-stocking fee if returned for credit, regardless if a defect is discovered or not. Re-stocking fees may 
vary depending on the condition of the item being returned, and whether it can be determined as in brand new 
condition. The warranty terms do not entitle customers to an automatic full refund. For more details on returns 
procedures and re-stocking fees, contact the agent. 
6. Items with physical signs of surge damage are not covered by warranty. Items without visible signs of surge 
damage will only be covered by warranty provided photographic evidence is provided from site showing surge 
protection has been installed as per instructions in this manual. 

 
 
 

 

 

Summary of Contents for CELLPRIM4GE

Page 1: ...FOR PROFESSIONAL USE ONLY Cellular Intercom System Note For legal reasons telephone technical support is for registered and qualified product dealers only Home owners and end users should contact the...

Page 2: ...n Programming a New Install Pg 12 Begin Programming Existing Install Pg 12 Programming Check Reception Pg 13 Activate clock sync Pg 14 Activate daily activity Pg 14 Program dial out and dial in number...

Page 3: ...BEFORE going to site Program the unit in the comfort of your work bench and call technical support should you have questions This product requires a SIM card from either At T or T Mobile however T Mo...

Page 4: ...nt door Optional Keypad Architectural Wall Mount Traditional Hooded Wall Mount Security Screw Access Open top screws only Hinged front door Microphone Built in antenna Security access key Pedestal Mou...

Page 5: ...ection Optional Prox reader module Optional Prox Coil Cable Entry Hole Mounting Holes Wall Mount Version Cellular Module Lock Push button Cellular PCB Optional Prox Coil Optional Keypad module Optiona...

Page 6: ...sible Maintain manufacturer s warranty by adhering to the guidelines shown Use 110v surge protected supply Surge protected 110v 4 24v dc PSU 16 gauge MIN 1 25 feet MAX Call box 2 Remove 4 screws and r...

Page 7: ...re Use 110V surge protection to maintain warranty Wall or Pillar side view IMPORTANT 18 gauge MIN 10 feet MAX Wall mount call station 1A quick blow input fuse Power Module in Detail Earth Rod MUST be...

Page 8: ...or door Magnetic lock Exit button Separate lock Power supply not supplied Wiring Relays Start Common Gate Position Limit switch optional Electric Gates Exit Button To Call Button 12v dc 100mA backlig...

Page 9: ...ections 3 24v out GND Slave IN connections Slave IN Slave OUT Optional PROX module Baud jumper remove for older intercoms Keypad Module To next device Optional Keypad Optional Prox reader Optional Sla...

Page 10: ...uld illuminate CPU Flashing standby Constant ON OFF busy SIGNAL STRENGTH 1 flash poor 1 bar 2 flashes low 2 bars 3 flashes good 3 bars 4 flashes Strong 4 bars 5 flashes searching POWER MODEM Flashing...

Page 11: ...much easier You can search store or scan QR code below Note You may notice the app BFT Cellbox Prime on the store This is for the home owner Installers should install the BFT Cellbox Programmer app A...

Page 12: ...Engineers and user pass codes are at default then do not change these Now you are ready to begin programming Programming an EXISTING Install 1 Go to MORE CLIENT LIST to reveal the screen shown 2 Press...

Page 13: ...take IMMEDIATE action Change network if possible or use an optional high gain antenna Check power cable is within recommended specification Poor power cable can lower reception SMS message sent to int...

Page 14: ...rd in the intercom Step 3 Activate Daily Activity This feature is needed for 2 reasons 1 To prevent some cellular carriers disconnecting the 4G LTE due to inactivity on the device 2 To keep time synch...

Page 15: ...elete ALL caller ID numbers and start again Step4 Programming Numbers for the intercom to call on button press 1 Press the SINGLE home icon for a 1 button system or MULTI for a 10 button system 2 Simp...

Page 16: ...Volume Avoid voicemail picking up un answered calls Service Calls prevent SIM being turned off due to inactivity Diagnostics Programmer and user pass codes Default relay pulse times Turn on SMS notif...

Page 17: ...number to avoid voicemail picking up a call on un answered call so the unit can roll over to the next number Note Default 20 secs includes 5 8 sec connection time Dialling time for first number defaul...

Page 18: ...ll call or SMS at the time at which the feature was activated So if you set this feature up at 5pm it will make the service call or SMS at 5pm at the next interval SMS string for choosing SMS or CALL...

Page 19: ...tus of the input terminals called STATUS on the intercom can be used with a limit switch Relay status shown to check if any relay is latched Last 5 digits of phone number which answered the gate Last...

Page 20: ...any further programming If the 1234 user access code is changed then you will also need to change it on the home owners app SMS Strings 9999 01XXXX X new programmers code 9999 02XXXX X new user acces...

Page 21: ...ed to trigger the gates and grant access Quick Enable disable this feature Enter the phone number to receive the SMS alert and press SAVE Enter text which you want the user to receive when access is g...

Page 22: ...4 digit format no colon and separate with comma e g 0800 2300 Select days up to 7 3 digit format separate with commas E g mon tue wed thu fri 4 digit code Permanent Keypad Code Stores up to 200 codes...

Page 23: ...n Delete any known code Delete ALL codes SMS String for deleting a known code 9999 84code Pass code Function code Code to be deleted Deleting ALL codes 9999 84 Temporary Code Stores up to 30 codes at...

Page 24: ...entary latch unlatch 2 Choose the days 3 Enter the time in military 24hr format without colon E g 8 30am 0830 11 10pm 2310 1234 1 day day day time USER passcode Command 1 trigger relay 1 2 latch relay...

Page 25: ...during pre set times and ignore button presses all other times Use this screen to set the ACTIVE times and days for the button Quick enable disable button Select start and finish times for the button...

Page 26: ...ses it can call the office phones during business hours and then call a security guard after hours 1 Enter phone number to call after hours 2 Enter button number enter 1 for single button system 3 Pre...

Page 27: ...3 Enter end time 24hr format no colon or spaces SMS String for time restricted code 9999 83 day day day time1 time2 code Pass code Function code Enter start and end time in 24hr 4 digit format no colo...

Page 28: ...n card ID to be deleted by serial number and it will also show the last stored cards for each type of card Delete the last stored temporary card Delete the last stored time restricted card Delete any...

Page 29: ...nds 1 9999 1 sec 9999 45 Calling time for first number adjust this to avoid voicemail picking up a call 10 99 secs 20 secs 9999 46 Calling time for second number adjust this to avoid voicemail picking...

Page 30: ...84code Delete code Code known code to be deleted N A 9999 84 Delete all codes N A Notifications 9999 80X X 1 to disable X 2 to enable N A 9999 78XXX X phone number to send notifications to delete num...

Page 31: ...t in a mobile phone to verify it can make a call and has calling credit Disable any PIN code request if active on the SIM card Check the SIM is a standard voice capable SIM If you are unsure contact y...

Page 32: ...ent mobile cell phone or landline If it works on a different phone check the settings on the phone in question under DTMF tones Failure of DTMF tones to operate correctly is also a symptom of low rece...

Page 33: ...the following incurred due to a product defect Cost of attending site inconveniences labour rates time lost loss to or damage to property security breaches late payment clauses or breaches of any con...

Page 34: ...l interference and 2 this device must accept any interference received including interference that may cause undesired operation Output power listed is ERP below 1GHz for Part 22 and EIRP above 1GHz f...

Page 35: ...P a g e 35...

Page 36: ...ricas www bftaccess com Note For legal reasons telephone technical support is for registered and qualified product dealers only Home owners and end users should contact their local dealer for product...

Reviews: