INSTALLATION MANUAL
Logic
Definition
De-
fault
Cross out
setting
used
Optional extras
EXPI2
Configuration of
EXPI2 input
on input-output
expansion board.
1-3
0
0
Input configured as Start E command.
1
Input configured as Start I command.
2
Input configured as Open command.
3
Input configured as Close command.
4
Input configured as Ped command.
5
Input configured as Timer command.
6
Input configured as Timer Pedestrian command.
7
Input configured as Phot (photocell) safety.
8
Input configured as Phot op safety (photocell active during opening only).
9
Input configured as Phot cl safety (photocell active during closing only).
10
Input configured as Bar safety (safety edge).
11
*
Input configured as safety Bar OP, safety edge with inversion active only while opening, if while closing the
movement stops.
12
*
Input configured as safety Bar CL, safety edge with inversion active only while closing, if while opening the
movement stops.
EXPO1
Configuration of
EXPO2 output
on input-output
expansion board
4-5
11
0
Output configured as 2
nd
Radio Channel.
1
Output configured as SCA (gate open light).
2
Output configured as Courtesy Light command.
3
Output configured as Zone Light command.
4
Output configured as Stair Light.
EXPO2
Configuration of
EXPO2 output
on input-output
expansion board
6-7
11
5
Output configured as Alarm.
6
Output configured as Flashing light.
7
Output configured as Latch.
8
Output configured as Magnetic lock.
9
Output configured as Maintenance.
10
Output configured as Flashing Light and Maintenance.
11
Output configured as Traffic Light control with TLB board.
TRAFFIC
LIGHT PRE-
FLASHING.
Traffic light pre-
flashing
0
0
Pre-flashing switched off.
1
Red lights flash, for 3 seconds, at start of operation.
TRAFFIC LIGHT
RED LAMP
ALWAYS ON
Steadily lit red
light
0
0
Red lights off when gate closed.
1
Red lights on when gate closed.
*
Only active on FW ≥ 2.10
TABLE “C” – RADIO MENU (
RADIO
)
Logic
Description
Add start
Add Start Key
associates the desired key with the Start command
add 2ch
Add 2ch Key
Associates the desired key with the 2nd radio channel command. If no output is configured as 2nd Radio Channel Output, the 2nd radio chan-
nel controls the pedestrian opening.
erase 64
Erase List
WARNING!
Erases all memorized transmitters from the receiver’s memory.
Read receiver code
Displays receiver code required for cloning transmitters.
ON =
Enables remote programming of cards via a previously memorized W LINK transmitter.
It remains enabled for 3 minutes from the time the W LINK transmitter is last pressed.
OFF=
W LINK programming disabled.
32 -
ARES ULTRA BT A 1000 - ARES ULTRA BT A 1500
D812201 00100_03
Summary of Contents for ARES ULTRA BT A 1000