INSTALLING THE END POST 
 

In case of an end post, use a corner clamp to fix the top of the panel 
 
 
 

15 10/02/2015 – Nylofor

®

 City Installation Manual 

Summary of Contents for Nylofor City

Page 1: ...Nylofor City Installation manual EN...

Page 2: ...ontent 1 Components of the fencing system 1 The posts 2 The panels 3 The clamps 2 Installation of Nylofor City 1 Foundations 2 Install posts 3 Install panels 2 10 02 2015 Nylofor City Installation Man...

Page 3: ...1 Components of the fencing system 1 The posts 2 The panels 3 The clamps 2 Installation of Nylofor City 1 Foundations 2 Install posts 3 Install panels 3 10 02 2015 Nylofor City Installation Manual...

Page 4: ...as end posts and corner posts The posts are foreseen of the appropriate holes and inserts for the fixation of the panels Posts are covered with an aluminium post cap Posts can be installed in concrete...

Page 5: ...the pins on the bottom A top rail is mounted on top of the panel to have additional rigidity standard length 2505mm Neoprene strips are glued in between the top rail and the Nylofor F panel to avoid...

Page 6: ...n concrete mm Length of the posts on floorplate mm inserts 606 2500x606 1000 647 3 1006 2500x1006 1500 1047 3 1206 2500x1206 1750 1247 4 1406 2500x1406 2000 1447 4 1606 2500x1606 2200 1647 5 1830 2500...

Page 7: ...r clamps are also used for end posts They are fixed with Hexagon Socket Button Head screws ISO7380 M6x60 in stainless steel Nylofor clamps for Nylofor F The plastic clamps are fixed with Hexagon Socke...

Page 8: ...1 Components of the fencing system 1 The posts 2 The panels 3 The clamps 2 Installation of Nylofor City 1 Foundations 2 Install posts 3 Install panels 8 10 02 2015 Nylofor City Installation Manual...

Page 9: ...530mm with a tolerance of 5 mm To determine the dimensions of the foundations it is recommended to consult a specialized engineer to evaluate wind load and solar conditions and any other factors requi...

Page 10: ...can be attached ALIGNING THE POSTS Place a pin before the first post of the fence and another behind the last post Connect those pins with two guide ropes The lower guide rope should be between 20 and...

Page 11: ...2 recesses into which the posts fit perfectly The distance between the posts measured from center center should be 2530 mm with a tolerance of 5 mm Place the posts correctly aligned vertically and hor...

Page 12: ...BLING THE PANEL Glue the neoprene strips on the top of the horizontal wire of the panel Divide 3 strips over the complete width of the panel Slide the panel into the top rail Assemble a second panel n...

Page 13: ...stall panels INSTALLING THE PANELS Fasten the top of the panels with a metal clamp Fasten the other positions of the panels with the PA clamps Repeat these steps to complete the installation 13 10 02...

Page 14: ...2 Installation of Nylofor City 2 3 Install panels INSTALLATION ON FLOORPLATE The bottom clamp is fixed on the floorplate 14 10 02 2015 Nylofor City Installation Manual...

Page 15: ...2 Installation of Nylofor City 2 3 Install panels INSTALLING THE END POST In case of an end post use a corner clamp to fix the top of the panel 15 10 02 2015 Nylofor City Installation Manual...

Page 16: ...se a corner post with inserts on two adjacent sides Fasten the top of the panel with left and right corner clamps Only corners of 90 are possible In any other situation two posts have to be installed...

Reviews: