What is this test for?
Glucoflex-R Test Strips are intended for self-testing of blood glucose. The test uses a small drop of
capillary blood (5 microlitres) to provide a semi-quantitative result. The test is not intended for use with neonates.
What is the purpose of glucose testing?
High blood glucose causes serious harm to the body over time. This damage
can be prevented by keeping blood sugar at normal levels. Studies have shown that the better the control of blood
glucose, the better the long term health of a person with diabetes. Regular self-testing with Glucoflex-R will provide
useful information for both you and your healthcare professional in managing the disease. Repeated testing allows you to
see the impact of diet, exercise and your medicine on blood sugar levels. Your healthcare professional will advise you on
when you should test and your target glucose range. Please note that blood glucose testing should only be undertaken
after you have received a thorough course of instruction from a qualified healthcare professional. Self-testing is not to be
seen as a substitute for regular monitoring by your doctor. It can however, allow your doctor to check your blood glucose
management. You should only adapt your treatment if you have been trained to do so.
What is included?
Glucoflex-R Test Strips (see outer packaging for quantity), 1 label with colour chart, instructions for use.
What is not included but needed?
A watch with a second hand or a timer, a clean white tissue, a lancing pen with lancet.
Product information
Storing the test strips
Store Glucoflex-R Test Strips in their original container in a cool, dry place between 2-30˚C (35-85˚F). Keep away from
heat and direct sunlight. Do not freeze. If stored in a refrigerator, remove and warm to room temperature before opening.
In the original bottle these test strips are stable up to the expiry date. Recap container immediately after removing strips.
Use before the expiry date.
How to perform a test
This test has an important timing step. Incorrect timing will give incorrect results.
You need a timer or a watch with a second hand, a clean white tissue and a lancing pen with lancet.
Watch a video demonstration at
www.betachek.com/gfx
1. Preparation –
Wash hands with soap and WARM water and dry them thoroughly. If you use
an alcohol wipe, make sure your finger is completely dry before testing. Remove a test strip
and immediately recap the container. Check the test zone against the “0 Unused” section of
the colour chart on the label. If the test zone shows any sign of blue you should discard the
test strip.
2. Obtain blood sample –
Use your lancing pen according to its instructions to prick your
finger. Gently squeeze the selected finger at the base moving toward the tip. This should be
repeated several times until you have a large hanging drop of blood (the palm of your hand
should be facing down so the drop can hang from the finger).
3. Apply blood –
Place the strip on a firm level surface or if preferred hold the strip moving it
towards the blood drop. Allowing the drop of blood to hang off the finger, press the drop onto
the centre of the two pads, moving it around to ensure complete coverage. Avoid touching the
pads with your finger. As soon as you have applied the blood to the pads start timing. Blood
should completely cover both pads. If you have smeared the blood or not used sufficient blood
to completely cover both the pads then you should repeat the test.
4. Wipe blood off –
Exactly 30 seconds after applying the blood, wipe the blood from the test
pads with a tissue. Repeat the wipe using a clean region of the tissue. Ensure the test zone is
clean of blood. Excess blood left on the pads will affect the result.
5. Read results –
After wiping the test zone wait another 30 seconds (1 minute from
applying blood), then compare the test zone to the colours on the label chart.
1.
4.
5.
60 sec
2.
0 sec
3.
30 sec
www.betachek.com/gfx
INSTRUCTIONS FOR USE
Glucoflex-R Blood Glucose Test Strips
Colourimetric visually readable. Suitable for self-testing
Glucoflex-R product improvements
(please review test procedure)
:
* 60 second test
* Plasma calibrated