TECHNICAL PARTICULARS
.
Model
.
Temperature range
............
D: S
1760/IR800..........
-50.to.800.
℃ (-58℉ ~ 1472℉) 20:1
Display.resolution.......
0.1.
℃ (0.1℉)
<1000
1℉
>1000
Accuracy.for.targets:
Assumes.ambient.operating.temperature.of.23.to.25.
℃ (73 to 77℉)
-50 ~ 20℃ (-58℉ ~ 68℉)
±2.5℃ (4.5℉)
20℃ ~ 300℃ (68℉ ~572℉) ±1.0% ±1.0℃ (1.8℉)
300℃ ~ 800℃ (572℉ ~ 1472℉) ±1.5%
.
Repeatability.....
-50 ~ 20℃ (-58~68℉):
±1.3℃(2.3℉)
20 ~ 800℃ (68~1472℉):
±0.5% or ±0.5℃(0.9℉)
Response.time.......
150ms
Spectral response
8~14µm
Emissivity
Digitally adjustable from 0.10 to 1.0
Over range indication
LCD will show “----”