32
Target Temperature [50]
Input value range: [0~127]
Tolerance of Temperature [0]
Input value range: [0~7]
Fan Out Start-Up Value [127]
Input value range: [0~255]
Fan Out Stop Value [100]
The Fan Out value decreases to this minimum value if the temperature is below the lowest temperature limit.
Input value range: [0~255]
Fan Out Stop Time [60]
Determines the amount of time it takes for the the Fan Out value to fall from the stop value to zero. Input
value range: [0~255]
Critical Temperature [75]
Determines the amount of time Fan Out takes to decrease its value by one step. Input value range: [0~255]
Fan Out Step Up Time [10]
Determines the amount of time Fan Out takes to increase its value by one step. Input value range: [0~255]
Fan Out Step Down Time [10]
Determines the amount of time Fan Out takes to decrease its value by one step in intervals of 0.1 seconds.
Input value range: [0~255]
PWM/DC Voltage Output [255]
Sets the voltage allocated for Fan Control. Input value range: [0~255]
The following items are available only when Fan Control Mode is set to [Speed Cruise Mode].
Target Speed [0]
Input value range: [0~4096]
Speed Tolerance [2]
Input value range: [0~64]
Fan Out Step Up Time [10]
Determines the amount of time Fan Out takes to
increase its value by one step. Input value range:
[0~255]
Fan Out Step Down Time [10]
Determines the amount of time Fan Out takes to
decrease its value by one step in intervals of 0.1
seconds. Input value range: [0~255]
Summary of Contents for MEB-7600
Page 1: ...1 Embedded System MEB 7600 Always at the forefront of innovation User Manual...
Page 6: ...6 Chapter 1 General Information...
Page 9: ...9 Figure 1 1 System Layout of MEB 7600 1 3 System Layout...
Page 10: ...10 Front View Rear View 1 4 Indicators Features...
Page 11: ...11 Chapter 2 Preparation...
Page 20: ...20 Chapter 3 Operation...
Page 24: ...24 Chapter 4 BIOS Setup...
Page 39: ...39 Chapter 5 Q A...