BestCode Next Series 8 Technical Manual
October 2022
Page 20 of 290
Verify the Modulation
Process Time: 30-75 minutes (depending on ink viscosity)
A video guide is available here:
1.
Run until the Viscosity is within range of
the Target Viscosity. (4.0-5.0cP).
2.
Locate the Calibration label inside the
Air Service Entry Door.
Note: These values are generated by
testing the machine at 20C controlled
environment.
Different temperatures and ink types
will vary the modulation set point.
3.
Decrease modulation to 30V below the
set point and test the print.
4.
Increase the modulation to 30V above
the set point and test the print.
a.
If the print is not acceptable,
perform a modulation calibration:
5.
Return the Modulation to the set point
and inspect the drop breakup.