BestCode Next Series 8 Technical Manual
October 2022
Page 10 of 290
Environment Selection
The installation environment is an important factor in selecting the correct machine to install.
Controller Environments
Model
Condition
81, 82, 86, 87
88,88SS, 88FG, 88SOP
88SHS, 88SHSOP, 88SM, 88SHS1,
88SOPHS1
0-5°C
Not Recommended
Add -DRY
Add -DRY
45-50°C
Ok
Ok
Ok
Washdown
Ok
Ok
Ok
Steam Clean
Not Recommended
Add -DRY
Add -DRY
Condensation
Not Recommended
Add -DRY
Add -DRY
Freezer
Not Recommended
Add -DRY
Add -DRY
Salty or Acidic
Add -316
Add -316
Add
–
316
High Dust
Recommend add -DRY
Recommend add -DRY
Recommend add -DRY
Dirty
Ok
Ok
Ok
Outdoors
Not Recommended
Add -DRY-316
Add
–
DRY-316
Wet Conveyor
Add -POSAIR
Add -POSAIR Or
Add -DRY
Add -POSAIR Or
Add -DRY
Controller system add-ons
-316
Controller is made from 316 Stainless for greater corrosion resistance
-DRY
System runs on compressed air and prevents all dust and water from entering into the electronics
area of the cabinet. Includes air drier attached to system. See
-POSAIR
Add on air pump for prevent dust, dirt, or water build up in the printhead. See
Printhead Selection
Printhead Environment
Model
Condition
81, 82, 86, 87
88,88SS
88FG, 88SOP
88SHS, 88SHS1,
88SHSOP,
88SOPHS1
88SM
Limited space
Add -90DPH
Add -90DPH
Add -90DPH
X
Printing on bottom of product
Add -90DPH
Add -90DPH
Add -90DPH
X
Character height less than 0.0
5”
X
X
X
OK
Darker Print
Add -75u
Add -75u
X
X
Print distance greater than ¼”
Add -75u
Add -75u
X
X
Longer distance from head to
controller
Add -15ft
Add -15ft
Add -15ft
Add -15ft
Dusty, Dirty, or Wet Conveyor
Add -POSAIR
Add -DRY Or
Add -POSAIR
Add -DRY Or
Add -POSAIR
Add -DRY
Or Add -POSAIR
Printhead system add-ons
-90DPH
Printhead L-shape to allow extra mounting clearance.
-75u
Increased nozzle size. Travels farther and prints darker.
-15ft
Extra length on the umbilical. Allows head to be mounted farther from the controller.
-DRY
Cooling system runs on compressed air and prevents all dust and water from entering into the
electronics area of the cabinet. Includes air drier attached to system.
-POSAIR
Add on air pump for prevent dust, dirt, or water build up in the printhead.
Summary of Contents for Next 8 Series
Page 2: ......
Page 3: ......
Page 4: ......
Page 143: ...BestCode Next Series 8 Technical Manual October 2022 Page 129 of 290 USB ...
Page 144: ...BestCode Next Series 8 Technical Manual October 2022 Page 130 of 290 Collector Information ...
Page 259: ...BestCode Next Series 8 Technical Manual October 2022 Page 245 of 290 ...
Page 264: ...BestCode Next Series 8 Technical Manual October 2022 Page 250 of 290 ...
Page 268: ...BestCode Next Series 8 Technical Manual October 2022 Page 254 of 290 ...
Page 276: ...BestCode Next Series 8 Technical Manual October 2022 Page 262 of 290 Using the Molex Crimper ...
Page 277: ...BestCode Next Series 8 Technical Manual October 2022 Page 263 of 290 ...