Nozzle Flow Test
Testing the flow at the nozzle is helpful in diagnosing clog issues. A failure of the Nozzle Flow Test would indicate a clog or
restriction in the prior fluidic components on the ink flow line. Review the
chart.
Step 1:
Confirm Bleed valve is working prior to performing this test.
Step 2:
Remove the inlet tube from the Printhead
Manifold to the Drop Generator.
Set bypass into a graduated cylinder.
Step 3:
Open the gutter valve and
set the pressure to 40 PSI.