Maintenance plan
Regular inspections shall be made according to national regulations by a trained and qualified
person. The number of service occasions shall be in accordance with national requirements. This
is especially important when the installation concerns a fire-approved door or a door with an
emergency opening function. Refer to Besam Pro-Active Care option services to learn more about
service possibilities!
As with all other technical products, an automatic door needs maintenance and service. It is essential
to know the importance of maintenance to have a reliable and safe product.
Service and adjustments will ensure a safe and proper operation of an automatic door unit.
The table below shows the recommended interval, in months, when to replace parts during pre-
ventive maintenance.
Abusive
Environment
Cycles/hour in operation
Part number
Part
>100
<100
<10
High
traffic
Medium
traffic
Low
traffic
6
6
12
24
330000271 SI/BK
PUSH arm service kit
6
6
12
24
330000272 SI/BK
PULL arm service kit
6
6
12
24
330000276
Stop arm kit
6
6
12
24
330000275
Micro switch kit
6
6
12
24
330000270
Adaptor kit
60
60
60
60
331007291
Transmission unit
60
60
60
60
331007504 BK
Connection box kit
60
60
60
60
331008346
Control unit CU-200 with EXU-
boards
73
Issue 2013-02-10
1009937-EI-1.0
17 Maintenance plan