Chapter 2 Operation
13
1
Reading in count rates is started with the „Cal.“ button.
Push „Clear“ to abort the count rate reading-in process.
While reading in the count rate, the remaining
averaging time appears on the display instead of
the code number. The averaged count rate is
displayed in the bottom row. You can change the
start time for averaging in code 37.
2
If the counting time is over, the average value is automatically
stored.
The new count rate has been determined and stored.
Note!
The process is automatically aborted after 1200 s at the latest.
2.2.1
Measurement Mode
In the regular measurement mode the measured value is displayed
in percent in code "10", or the count rate in cps in code 11.
If code 10 (11) is not displayed, push the Clear button (for 2 sec-
onds) to jump to the result display.
The reading in % may fluctuate significantly around 0% if the con-
tainer is empty, but it must not get close to the switching thresh-
old defined in code 18. To prevent this, the time constant in code
12 has to be big enough or the program has to be set to the au-
tomatic mode.
Note!
The reading in % allows you to check the measured values during
operation. If you get significantly different values, for example,
due to product caking, you may perform a re-calibration any time.
20 minutes after a button has been pushed for the last time, the
program automatically goes to code 10 or code 11, provided these
codes are not yet displayed. In code 15 you can define if code 10
or code 11 is the standard result display.
59s
60
Summary of Contents for LB4710-050
Page 2: ......
Page 4: ......
Page 8: ......
Page 32: ......
Page 33: ...Chapter 3 Functional Safety Mini Switch LB 471 33...
Page 34: ...Chapter 3 Functional Safety Mini Switch LB 471 34...
Page 35: ...Chapter 3 Functional Safety Mini Switch LB 471 35...
Page 44: ......
Page 58: ......
Page 98: ......
Page 104: ......
Page 110: ...Chapter 14 Certificates Mini Switch LB 471 110...
Page 111: ...Chapter 14 Certificates Mini Switch LB 471 111...
Page 112: ...Chapter 14 Certificates Mini Switch LB 471 112...
Page 113: ...Chapter 14 Certificates Mini Switch LB 471 113 14 2 ATEX Certificate NaI Detector...
Page 114: ...Chapter 14 Certificates Mini Switch LB 471 114...
Page 115: ...Chapter 14 Certificates Mini Switch LB 471 115...
Page 116: ...Chapter 14 Certificates Mini Switch LB 471 116...
Page 117: ...Chapter 14 Certificates Mini Switch LB 471 117 14 3 ATEX Certificate GM Detector...
Page 118: ...Chapter 14 Certificates Mini Switch LB 471 118...
Page 119: ...Chapter 14 Certificates Mini Switch LB 471 119 14 4 EC Declaration of Conformity...
Page 120: ......
Page 141: ...Mini Switch LB 471 141 Notes...
Page 142: ...Mini Switch LB 471 142 Notes...
Page 145: ......
Page 147: ......
Page 149: ......
Page 151: ......
Page 161: ......
Page 195: ......
Page 215: ......
Page 219: ......
Page 223: ...Mini Switch LB 471 78 Notes...
Page 224: ...Mini Switch LB 471 79 Notes...
Page 227: ...Mini Switch LB 471 82 Y Year 21 Z Zero count rate 8 30 32 58...