Level 0: switched off
Level 1: low oil flow
Level 4: medium oil flow
1
0
2
3
4
5
6
7
8
9
Level 9: high oil flow
5.2
Refill
Refilling the chain oil is easy and fast. The syringe can be raised directly
on the cap of the oil bottle. The end cap of the filler pipe can be removed
by pushing the locking edge. With the syringe, oil can be filled into the
system. The oil tank is bleeding automatically. This has to be repeated
until the oil tank is full, but don’t overfill the tank, otherwise oil will leak out
of the ventilation of the tank.
5.3 Check and Maintenance
After the installation do some visual inspection to check the correct
setting of the oil flow.
The oil level of the oil tank should be checked and refilled every 1700
miles (long range tank every 3400 miles). Thus you can avoid the system
running dry.