![Bernecker + Rainer 4MP181.0843-03 User Manual Download Page 25](http://html1.mh-extra.com/html/bernecker-rainer/4mp181-0843-03/4mp181-0843-03_user-manual_2738002025.webp)
Technical Data • Entire Device
Chap
ter 2
Tec
hni
cal
Data
25
Mobile Panel User's Manual V 1.5
2.2 Technical Data
Features
5.7“ Display Versions
8.4“ Display Versions
Power Supply
Rated Voltage
Starting Current
Power Input
Electrical Isolation
24 VDC ± 25%
for short time (approx. 1 ms) 20 A
Approx. 8 Watt typically, max. 10 Watt
-
Safety Elements / Entry Devices
E-stop Button
Key Switch
Enable Switch
Current Load
2 N.C., right position in the operating unit
1 N.O., left position in the operating unit
3-step, 2-channel, front position on the handle
See Section"Current Load of the Enable Switch and Entry Device Circuit", on page 92
Mechanics
Operating Unit
Material
Paint, Color
Double-walled housing from plastic (Cycoloy C2950)
Soft-touch coating, similar RAL7016
Handle
Material
Paint, Color
Plastic (pure compact foam)
Soft-touch coating, similar RAL7016
Outer Dimensions in mm (WxHxD)
Without Handle
With Handle
306.6 x 76 x 270.8
306.6 x 152.6 x 270.8
Weight
(without handle, Compact Flash card and
connection cable)
(without handle, Compact Flash card, without
connection cable)
1650 grams
2210 grams
1900 grams
2460 grams
Environment
1)
Environmental Temperature
Operation
Storage
Transport
0 °C to 45 °C
-20 °C to +60° C
-20 °C to +60° C
0 °C to 45 °C
-20 °C to +70 °C
-20 °C to +70 °C
Humidity
Operation
Storage
Transport
45 % to 85 %, non-condensing
8 % to 85 %, non-condensing
8 % to 85 %, non-condensing
Vibration
Operation (continuous)
Operation (occasional)
Storage
Transport
Max. 9 - 200 Hz and 0.5 g (4.9 m/s² 0-peak)
Max. 9 - 200 Hz and 1 g (9.8 m/s² 0-peak)
Max. 2 -500 Hz and 4 g (39.2 m/s² 0-peak)
Max. 2 -500 Hz and 4 g (39.2 m/s² 0-peak)
Shock
Operation
Storage
Transport
Max. 15 g (147 m/s² 0-peak) and 11 ms length
Max. 30 g (980 m/s² 0-peak) and 11 ms length
Max. 30 g (980 m/s² 0-peak) and 11 ms length
Height above Sea Level (operation)
2000 meters
Drop Height
1 meter on industrial surfaces
Flame Resistant
UL94V-0
Protection
IP54 (with mounted handle)
Table 11: Entire device
Summary of Contents for 4MP181.0843-03
Page 2: ...2 Mobile Panel User s Manual V 1 5...
Page 4: ...4 Mobile Panel User s Manual V 1 5...
Page 6: ...6 Mobile Panel User s Manual V 1 5...
Page 134: ...134 Accessories USB Memory Stick Mobile Panel User s Manual V 1 5...
Page 144: ...144 Maintenance Servicing Changing the Battery Mobile Panel User s Manual V 1 5...
Page 160: ...Model Number Index 160 Mobile Panel User s Manual V 1 5...