2
6T 7973-31a
Caution:
- This device must be installed only by
a qualified electrician according to the
installation standards in force in the
country.
1
6T 7973-31a
6T
79
73
-3
1a
Order no.
8536 52 00
Berker GmbH & Co. KG
Klagebach 38
58579 Schalksmühle/Germany
Telefon: + 49 (0) 23 55/90 5-0
Telefax: + 49 (0) 23 55/90 5-111
05/2012
97-85365-200
§
Operation instructions
15 min
s
5 min
auto
-
+
lux
test
30
α
Description
Detection zone
Installation
Adjustments
Shutters
Angle fixing support 8590 02 00
Optimal installation height is 2.5m.
The detection zone shall remain free of obstacle.
8 m
16 m
2,5 m
0,5 m
16 m
4 m
LED
A
LED
B
Delay
(lighting time)
Brightness
level
Sensitivity
(change
of range)
1
2
IP55
+ 90°/- 30°
+/-80°
Wall fixing plate
Adjustment potentiometers
Directional detection head
Vertical adjustment
Button
J
cfg
cfg
LED cfg
Button
J
Test and validation of detection
zone
Set potentiometer
2
to mode "
auto test
".
O
The test mode is available only once the
product has been configured.
The Test mode is available for 3 minutes time
and does not take brightness level into
account.
Each detected movement turns LED
A
on for
2 seconds.
The associated receiver is not under control.
After 3 minutes without detection, the product
is set back to auto mode.
Limitation of detection zone :
You can limit the detection zone using the
shutters supplied or by inclining the head.
Mounting
Projection or ceiling mount :
- Fix the wall plate using the supplied screws.
- Clip the detector onto the wall plate
- Tighten the screws to close.
For angle mounting, the wall fixing plate is
fitted between the accessory and
the detector.
Precautions for installation
For optimum detection conditions, please
follow these recommendations :
- Keep the detector protected from bad
weather, as it is sensitive to these conditions.
- Maintain 1m distance between the light
source and the detector and keep the
detector out of the light source.
Product Description and working
principles
This detector allows remotely control of one
or more receivers for a given time when a
movement is detected in its detection zone.
This product can be used in two types of
configuration: one detector controls
one/several receiver(s); several transmitters
control the receiver(s).
Operation
The receiver(s) is(are) under control as soon
as the brightness level as set by potentiometer
2
is considered too low and a movement is
detected.
Upon detection, the time delay is restarted.
If LED
A
flashes quickly during configuration,
the position of potentiometer
1
is not compa-
tible with the selected function.
Product factory reset is recommended before
any new configuration.
Factory reset
Keep push-button
J
depressed until LED
cfg
flashes (>10s), and then release it.
LED
cfg
is turned off when factory return is
completed.
After factory return, wait 15 s before starting
configuration.
Action
Adjustments
Potentiometer
Use Auto (factory)
settings to set
automatic lighting
turn-on for
a given time.
Only available when
a detector’s time
delay is set.
Auto Settings
Put the Lux potentiometer on
“
auto test
”.
The settings are predefined :
Lux =
,
(operating at night only)
time = 3 min,
sensitivity = max
auto
lux
test
Turn automatic
lighting on for
a given time.
Only available when
a detector’s time
delay is set.
Installer settings
15 min
30 s
5 min
auto
-
+
lux
test
Adjust sensitivity.
Allows setting the range
to avoid disturbance.
-
+
Hereby, Berker GmbH & Co. KG, declares that this motion
detector output is in compliance with the essential require-
ments and other relevant provisions of Directive 1999/5/EC.
The CE declaration can be consulted on the site :
www.hagergroup.net
Usable in all Europe
and in Switzerland
Configuration (button
J
)
These detectors can be configured in 3 different
ways :
•
quick
link
&
: configuration without tool, directly
on the device via
J
button and LED (see
configuration instructions
quick
link
&
).
• tebis TX: configuration using connection device
from Hager
• ETS3/ETS4 via KNX-RF/TP gateway: database
and description of application software available
from the manufacturer.
Configuration by ETS
Press
J
button for addressing by means of
radio/KNX gateway.
O
Product factory reset is required to change the
configuration mode.
KNX-RF controller 220° solar