LED unit 

Wiring cut-off control 

The LED unit lights up when "ON". 

 ATTENTION! 

Short circuit by connection of the neutral conductor on installed contact bridge. 

 

LED unit will be destroyed. 

 

Remove contact bridge before connecting the neutral conductor. 

 

(3) 

(4) 

Figure 4 

„

 

Removing the contact bridge (Figure 4, 3). 

 

Behind the contact bridge is the screw terminal for connecting the neutral conductor  
(Figure 4, 4). 

 
97-09927-000

 

 

Page 3/4 

11/2011

 

L

L

N

rot

L

3036

 11

mm

L

N

 

Figure 5 

„

 

Connect switch acc. to wiring diagram (Figure 5). 

 