Fig. 22
2.
Turn center plate knob CW until resistance stop.
3.
Check slicer for proper operation.
Center Plate Knob Removal
1.
Remove center plate as outlined above.
2.
Remove retaining ring from back side of knob.
Fig. 23
3.
Remove knob.
4.
Reverse procedure to install.
5.
Check slicer for proper operation.
KNIFE
Knife Removal
Disconnect the electrical power to
the machine and follow lockout /
tagout procedures.
Electrical and grounding connections must
comply with the applicable portions of the
National Electrical Code and / or other local
electrical codes.
NOTE:
Replace knife if it is less than 12-3/4"
diameter.
1.
Remove product table as outlined under
PRODUCT TABLE.
2.
Reach under slicer and pull slide bar toward arm
assembly.
Fig. 24
3.
Open gauge plate and tape knife edge.
Fig. 25
4.
Remove bolt and washer.
NOTE:
Place #2 phillips driver in knife hole against
lower ring guard mount. Use a rag to protect the ring
guard mount and slicer body.
X13 SLICER - REMOVAL AND REPLACEMENT OF PARTS
Page 13 of 36
F25332 Rev. A (0718)