USER HANDBOOK 1.0 | B-PRIMIS ET-PRO SERIES
Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | Germany | www.berghof-automation.com
S_B-Primis_ET-Pro_DE_1_0_EN_neu.docx
40
Fig. 28
: Device’s network settings
4th
If necessary, press the ”Edit” button and change the network setting accordingly (IP address, net
mask, gateway).
5th
Press the ”Next” button.
The page with the device’s Network Settings appears.
Fig. 29: Setting the server IP
6th
If necessary, press the ”Edit” button and change the server IP.
7th
Press the ”Expert” button to change the lifeguard setting.
The page with the expert settings appears.
– or –
Press the ”Next” button and skip the following step.
Fig. 30: Changing the Lifeguard settings
8th
Change the lifeguard setting via the ”Change” button according to the version of the controller:
CODESYS V2: “Berghof VNC LG”
CODESYS V3: “Ping LG”