USER MANUAL 2.2 | B-EASYCONNECT
Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | www.berghof-automation.com
23
5.1.5 Operation as WLAN Client Mode
– with static IP-Address
Fig. 7: Operation as WLAN-Client Mode
– with static IP-Address
1.
Enter the parameters of the WLAN network to which the gateway or controller is to connect.
A connection can only be established if the network has been set up with WPA2 encryption.
2.
IMPORTANT: Select WLAN Country according to the operating location!
3.
STATIC Mode - the client uses a static network configuration.
4.
Network configuration of the client - must be selected according to the network
configuration of the access point. The IP address must not come from the DHCP range of
the access point.
5.
Accept and save the configuration - the settings are active after a restart of the controller.