This defines the most recent faults. The two left most digits are the fault code, and the right
most is elapsed time in 0.1 hr increments since the last restart of the drive, 0.9 hours max.
See chapter 8.2, page 62.
Inverter output frequency (Hz) applied to the motor.
◊
Value range: 0.00–400.0 Hz
Motor output voltage calculated as a percent of applied line input voltage.
◊
Value range: 0–100% of the mains voltage
Motor phase current computed to an accuracy of ±20%.
◊
Value range: 0.00–60.00 A
True part of motor current. Output current measurement with motor power factor applied.
Accuracy is ±20%. Load reading is positive in motoring mode, and negative in regenerative
mode.
◊
Value range: 0–200% of
03-IRAT
Inverter heatsink temperature. The inverter will turn off when this temperature exceeds its
maximum allowed temperature. Accuracy is ±3 °C.
◊
Value range: 0.00–110.0 °C
The
21-MODE
parameter defines the source for speed reference and Run/Stop control in-
put.
MODEL
NUMBER
VALUE OF
03-IRAT
MODEL
NUMBER
VALUE OF
03-IRAT
3300-3
2.0 A
3602-2
5.5 A
3300-5
3.6 A
3603-0
9.0 A
3300-7
6.8 A
3604-0
9.0 A
3301-1
6.8 A
3605-5
13.0 A
3301-5
9.6 A
3607-5
18.0 A
3302-2
15.2 A
3611-0
24.0 A
3600-7
2.0 A
3615-0
30.0 A
3601-5
3.7 A
Table 5.1
07-FLT3
– Last Fault
1V
08-FLT2
– Second Fault
2V
09-FLT1
– First Fault
2V
12-FOUT
– Motor Output Frequency
[Hz]
1V
13-VOUT
– Motor Output Voltage
[%]
1V
14-IOUT
– Motor Output Current
[A]
1V
15-LOAD
– Inverter Load
[%]
1V
17-TEMP
– Inverter Temperature
[°C]
1V
21-MODE
– Input Mode
1P