12
ENGLISH
table 2
MINIMUM NUMBER OF FAN
ROTATIONS
METHANE
GAS (G20)
LIQUID
GAS (G31)
12 R.S.I.
13
18
rpm
25 C.S.I. - 25 R.S.I.
17
17
rpm
30 C.S.I.
14
14
rpm
35 R.S.I.
14
14
rpm
38 C.S.I.
14
14
rpm
table 3
MAXIMUM CO
2
METHANE
GAS (G20)
LIQUID
GAS (G31)
12 R.S.I.
9,0
10,0
%
25 C.S.I. - 25 R.S.I.
9,0
10,0
%
30 C.S.I.
9,0
10,0
%
35 R.S.I.
9,0
10,0
%
38 C.S.I.
9,5
10,5
%
table 4
MINIMUM CO
2
METHANE
GAS (G20)
LIQUID
GAS (G31)
12 R.S.I.
9,5
10,0
%
25 C.S.I. - 25 R.S.I.
9,5
10,0
%
30 C.S.I.
9,5
10,5
%
35 R.S.I.
9,5
10,0
%
38 C.S.I.
9,5
10,5
%
RANGE RATED
This boiler can be adapted to the heating requirements of the sys-
tem, in fact it is possible to set the maximum delivery for heating
operation of the boiler itself:
- switch off the power supply
- setting the heating water temperature selector at the maximum
value
- remove the shell
- turning the instrument panel towards you
- unscrew the two screws of the small cover on the electronic
board to have access to the terminals
- insert JP1 jumper
- power up the boiler
The display shows “ADJ” for about 4 sec.: it is then possible to
change the maximum heating value by means of the heating water
temperature selector and the CO button in order to set and confirm
the desired value.
The icon will appear on the display.
Finish the procedure by removing the jumper JP1 to store
the set values.
Once the desired output (maximum heating) has been set, note the
value on the table on the back cover.
For subsequent controls and adjustments, refer to the set value.
The calibration does not entail the ignition of the boiler. By ro-
tating the heating setpoint selector knob, the value expressed
in hundreds (e.g. 25 = 2500 rpm) is automatically displayed.
The boiler is supplied with the adjustments shown in the table.
Depending on plant engineering requirements or regional flue gas
emission limits it is, however, possible to modify this value, refer-
ring to the graphs below.
HTG curve (Qnheating)
Fan rotations (rpm)
Heat output (kW)
COs.a. curve (Qnheating)
CO emissions s.a. (p.p.m.)
Heat output (kW)
Mynute Green 12 R.S.I. E
1200
1400
1600
1800
2000
2200
2400
2600
2800
3000
3200
3400
3600
3800
4000
4200
4400
4600
4800
5000
5200
5400
5600
2
3
4
5
6
7
8
9
10
11
12
13
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
2
3
4
5
6
7
8
9
10
11
12
13
Mynute Green 25 C.S.I. E - 25 R.S.I. E
HTG curve (Qnheating)
Fan rotations (rpm)
Heat output (kW)
COs.a. curve (Qnheating)
CO emissions s.a. (p.p.m.)
Heat output (kW)
1000
1500
2000
2500
3000
3500
4000
4500
5000
5500
6000
4
6
8
10
12
14
16
18
20
22
24
26
40
50
60
70
80
90
100
110
120
130
140
150
4
6
8
10
12
14
16
18
20
22
24
26