12
Installation
6004347_0 – 27.09.2018
3.5.4
Hang the device in place
The device is designed to be hung on walls. The chimney can
be adapted to the ceiling height by pulling it out.
When mounting on a solid wall:
☞
Make sure that the wall has sufficient load bearing
capacity.
☞
Use the fastening materials provided.
With different installation situations:
☞
Enquire about alternative fastening systems (e.g. consult
with your architect).
☞
Only use fastening hardware suitable for the type of wall.
x
y
460
35
270
495
31
290
=
=
400
Safety distance (x):
y
Recommendation 650 mm.
y
With gas hobs, at least 650 mm.
Distance from upper edge of body to ceiling (y) =
Length of the chimney side parts + 2 mm
☞
Determine the hanging position.
☞
Ensure that the wall bracket is correctly positioned:
y
If dimension “y” is undercut then the front panel
cannot be opened.
☞
Make sure that the safety distance is complied with.
D
WARNING
Risk of death due to explosions or electric shock!
Drilling through gas, water or electrical lines can lead to
hazardous situations.
☞
Ensure that there are no lines in the wall at the fastening
points.
Ø 8
☞
Determine the locations of the fastening points and mark
them.
☞
Drill the holes in the wall.
☞
Insert the wall plugs into the holes.
☞
Screw the wall bracket on loosely.