background image

AMC10

MINI DOOR / WINDOW CONTACT

CONTATTO MAGNETICO VIA RADIO

CONTACT MAGNETIQUE

G

G

G

G

G

  ENGLISH

ISTISBLVAMC10  0.0  260404  P7.0

REMOVE COVER

At the notched location 

on the cover, insert the flat blade of a small screw-driver between the base and the cover

and  twist the  screwdriver  to  pop the  cover  off.

INSTALL BATTERY

Use care when installing the battery and observe the correct polarity (see Fig. 1). Use only an Eveready Lithium Energizer
No. EL123AP or
Teckcell  CR123A  battery.

!

!

!

!

!

WARNING! The Battery may explode if mistreated. Do not recharge, disassemble or dispose of in fire.

+

The warranty does not apply to the battery of the Magnetic contact.

Select the location where the transmitter is to be mounted. Perform the
Module 

Placement Test

 to ensure that the selected location is in range of the wireless receiver (see receiver Installation

Manual for instructions).

REMOVE CIRCUIT BOARD

Before mounting the unit, remove the circuit board. At the notched location on the base which is on the same side as
the reed switch, insert the blade of a small screwdriver between the base wall and the bottom of the circuit board and
pry the circuit board up.

!

!

!

!

!

Do not touch the coils 4 on the circuit board as this may damage the unit.

Mount the backplate of the transmitter using the screws 

8

 provided and replace the circuit board. The head of the

screw must be below the circuit board so that the sensor is not shorted out.

!

!

!

!

!

Use flat-headed screws only.

Close the Magnetic Contact

+

Use silicone to secure the Cover to the base, in order to avoid unintentional opening.

Mount the magnet no more than ¼" from the transmitter. Use the spacers provided. Once the unit and magnet are
mounted, open and close the window/door to ensure that none of the parts interfere with this movement.

+

Only one magnet can be used per transmitter.

USING EXTERNAL CONTACTS

The external contact terminals 

5

 can be used to connect external contacts or other switches/ devices to the universal

transmitter.  Install  the  additional  device  as  per  the  manufacturer's  instruction.  Connect  the  device  to  the  contact
terminals of the AMC10. The input is normally closed and is not supervised.

+

The resistance of the wires used for the connection of the external contact to the auxiliary input must not exceed100
Ohm. Only one contact can be used. If an external contact is used, do not install the magnet.

!

Use  of  the  auxiliary  input  will  void  the  IMQ-
SECURITY SYSTEM Certification.

TAMPER SWITCH

There is one tamper switch (

3

) on the AMC10 board.

Removing the cover will cause a zone tamper.

ENROLLING A AMC10

On the back of the door contact housing, there will
be  two  serial  numbers,  a  five  digit  and  six  digit.
Please refer to your receiver Installation Manual for
information on which serial number should be enrolled.

A

B

L I T H I U M

C R 1 2 3 A

3V

1

3

4

6

5

18

2

7

8

9

10

11

12

13

14

17

16

8

9

10

15

13

 N.

DESCRIZIONE

I

I

I

I

 1

Coperchio del Contatto

 2

Riferimento per l'apertura
del Contatto

 3

Pulsante Antisabotaggio

 4

Antenna

 5

Ingresso Ausiliario

 6

Ampolla reed

 7

Riferimento per la
rimozione della Scheda

 8

Viti (2) per il fissaggio del

Contatto

 9

Aperture (4) per i fili

canalizzati a vista o
sottotraccia

 10

Fori (2) per il fissaggio del
Contatto

 11

Distanziatore del Magnete

 12

Magnete

 13

Viti (2) per il fissaggio del

Magnete

 14

Coperchio del Magnete

 15

Fondo del Contatto

 16

Alloggiamento Batteria

 17

Scheda del Contatto

 18

Batteria

 No. DESCRIPTION

G

G

G

G

 1

Contact Cover

 2

Notch

 3

Tamper button

 4

Antenna

 5

Auxiliary Input

 6

Reed switch

 7

PCB lever point

 8

Contact screws (2)

 9

Wire entries (4)

 10

Contact screw locations (2)

 11

Magnet spacers

 12

Magnet

 13

Magnet screws (2)

 14

Magnet Cover

 15

Contact base

 16

Battery housing

 17

Contact board

 18

Battery

TECHNICAL SPECIFICATIONS

 Power Supply

1 x 3V Lithium battery:

Energizer EL123AP, Tekell CR123A,

Panasonic CR123A, or similar

 Operating Temperature

5 ÷ 40 °C

 Performance Level

I

 Size (W x H x D)

88 x 31 x 30 mm

 Weight (with battery)

58 g

 N.

DESCRIPTION

F

F

F

F

 1

Couvercle du contact

 2

Encoche

 3

Autoprotection

 4

Antenne

 5

Entrée Externe

 6

Ampoule Reed

 7

Point de levier

 8

Vis pour le contact (2)

 9

Passage de câble (4)

 10

Trous  de fixation (2)

 11

Cales pour l'aimant

 12

Aimant

 13

Vis pour l'aimant (2)

 14

Couvercle de l'aimant

 15

Embase

 16

Support de Pile

 17

Carte

 18

Pile

Hereby, Bentel Security, declares that this device is in compliance with the
essential requirements and other relevant provisions of Directive 1999/5/
EC.

The complete R&TTE Declaration of Conformity can be found at
www.bentelsecurity.com/dc.html.

I

I

I

I

I

 Fig. 1 

Parti e Installazione del Contatto Magnetico

E

E

E

E

E

 Fig. 1 

Parts and Installation of the Magnetic Contact

F

F

F

F

F

 Fig. 1 

Contact Magnétique Radio

E

E

E

E

E

  - 

The  Manufacturer  reserves  the  right  to  change  the  technical

specifications  of  this  product  without  prior  notice.

I

I

I

I

I

 

Le  specifiche  tecniche  del  prodotto  possono  subire  variazioni

senza  preavviso.

F

F

F

F

F

  - 

BENTEL  SECURITY  srl  se  réserve  le  droit  de  modifier  les

spécifications  techniques  de  ce  produit  sans  préavis.

Reviews: