SMS OPERATIONS
The operations described in this chapter are possible
only if the installer has installed the GSM Module in your
control panel and has carried out the respective pro-
gramming: ask your installer which operations are pos-
sible with your control panel.
+
Some of the operations described in this chapter
require you to send your PIN by SMS. To increase
the security of your system, once the operation re-
quested has been completed, you can disable your
PIN as described in the respective paragraph, so
that no one else can use it without your knowledge.
Events Controlled by Caller ID
You can activate some events (See Table 10) simply by
calling the control panel’s GSM number, at no cost.
When the control panel receives a call from one of the
Phone Numbers
listed in Table 10, it waits for a few
rings, then it hangs up and activates the respective
Event
: the control panel then confirms with one ring to
the phone number, if enabled to do so by the installer.
+
The ring for confirmation may be delayed if there
are other calls in the queue or it may be lost if the
queue is full or because of problems with the GSM
network.
Ï
The Absoluta 630 control panel does not make the
confirmation ring.
Events Controlled by SMS
Ï
The Absoluta 630 control panel does not support
this function.
3
In order to ensure compliance with EN50131
Grade 3 standards, Events Controlled by SMS may
NOT be used.
You can activate and deactivate events (Table 11) by
sending the following SMS to the control panel’s GSM
number:
#ABS#E#<PIN>#<ON|OFF>#<Command
String>#<Text>
Ø
PIN
: a User PIN enabled to manage the control panel
by SMS.
Ø
ON|OFF
: ON activates the event; OFF deactivates
the event.
Ø
Command String
: the string programmed by the in-
staller, which is NOT case-sensitive (see the
Com-
mand String
column in Table 11).
Ø
Text
: additional text that can be used to assign a de-
scription to the command message and is ignored by
the control panel.
+
The event is activated and deactivated ONLY if the
PIN and the event share at least one Partition (see
the
Partitions
column in Table 11).
+
The
OFF
command is not available if ONLY Mono-
stable Outputs are associated to the event as this
type of output is deactivated by itself after the pro-
grammed time has elapsed.
+
If Monostable and Bistable outputs are associated
to the event, the
OFF
command deactivates the Bi-
stable outputs ONLY while the Monostable outputs
are deactivated after the programmed time has
elapsed (ask your installer for more information).
+
The angle brackets () should NOT be included in
the message.
For example, lets suppose you want to trigger the event
with the
Command String
lights
and your PIN is 1234;
the SMS message will be:
#ABS#1234#ON#lights#
Partition Status
You can check on the status of the control panel’s Parti-
tions by sending the following SMS to the control
panel’s GSM number:
#ABS#A#<PIN>#<Text>
Ø
PIN
: a User PIN enabled to manage the control panel
by SMS.
Ø
Text
: an additional text that can be used to assign a
description to the command message and is ignored
by the control panel.
+
The angle brackets () should NOT be included in
the message.
Absoluta Plus and Absoluta 630
SMS OPERATIONS
71