9.5 Calibration
To maintain the specified precision of the measurement results, the instrument
must be recalibrated at regular intervals by our factory service. We recom-
mend a recalibration interval of one year. Send the appliance to the following
address:
Benning Elektrotechnik & Elektronik GmbH & CO. KG
Service Centre
Robert-Bosch-Str. 20
D - 46397 Bocholt
9.6 Spareparts
Fuse F 10 A, 500 V, 1.5 kA, D = 6.3 mm, L = 32 mm
P.no. 749726
0. Applicationofrubberprotectionframe
- You can store the safety measuring lines by winding the safety measuring
lines around the rubber protection frame
and engaging the tips of the
safety measuring lines with protection against the rubber protection frame
(see figure 13).
- You can engage a safety measuring line to the rubber protection frame
, that the measuring tip protrudes freely, in order to be able to apply the
measuring tip - jointly with the BENNING MM 8/ 9/ 10 to a measuring point.
- The rear support on the rubber protection frame
provides for an inclined
setup of the BENNING MM 8/ 9/ 10 (facilitates reading) or attachment (see
Figure 14).
The rubber protection frame
is fitted with a lug which can be freely used
for an attachment option.
see figure 13:
Winding up of the safety measurement line
see figure 14:
Assembly of the BENNING MM 8/ 9/ 10
. Technicaldataofthemeasuringaccessories
4mmSafetymeasuringcableATL2
- Standard: EN 61010-031,
- Maximum rated voltage to earth ( ) and measuring category: 1000 V
CAT III, 600 V CAT IV,
- Maximum rated current: 10 A,
- Protective class II (
), continuous double or reinforced insulation,
- Contamination class: 2,
- Length: 1.4 m, AWG 18,
- Environmental conditions:
Maximum barometric elevation for making measurements: 2000 m,
Temperatures: 0 °C to + 50 °C, humidity 50 % to 80 %
- Only use the measuring cables if in perfect condition and according to this
manual, since the protection provided could otherwise be impaired.
- Throw the measuring cable out if the insulation is damaged or if there is a
break in the cable/ plug.
- Do not touch the bare contact tips of the measuring cable. Only grab the
area appropriate for hands!
- Insert the angled terminals in the testing or measuring device.