Benning 044166 Operating Manual Download Page 10

2.4 Intended use

Safety

5186 / 07/2021 en

BENNING CC 4-1 / CC 4-2

10

2.4

Intended use

Only use the device within the framework of the corresponding technical data. Any operating
conditions that deviate from this shall be considered as improper use. Solely the user of the
device shall be liable for any resulting damage.

In particular, note the following:

• In case of improper use, the liability and warranty claims become void. Solely the user of the

device shall be liable for any damage resulting from improper use. Uses not complying with
the intended use include e. g.:

– Use of components, accessories, spare or replacement parts that have not been

released and approved for the respective application by Benning

– Non-observance, manipulation, changes or misuse of the operating manual or the

instructions and notes contained therein

– Any form of misuse of the device

– Any use other than or beyond that described in this operating manual

• Warranty and liability claims are generally excluded if damage is due to force majeure.

• If any prescribed services are not performed regularly or not on time according to

manufacturer specifications during the warranty period, a decision about a warranty claim
can only be made once the findings are available.

Direct any questions to Technical Support [

}

 page 7].

Using the device

Please observe the following basic obligations when using the device:

• The device may only be used in a technically perfect and safe condition. Always check the

device for damages before using it.

• Make sure the personnel using the device is qualified for the respective task.

• Observe relevant regulations on occupational safety and health as well as those on

environmental protection.

• The device may only be used in dry environments.

• Use the device only in electric circuits of overvoltage category III with a conductor for a

maximum of 600 V‑AC to earth.

• Do not apply any voltage to the outputs of the device.

 WARNING

Opening the device

Danger to life or serious injury is possible due to contact with high electric voltage when opening
the device. The device might get damaged.

• Do not open the device.

• Please contact your specialty retailer or the returns management [

}

 page 7] for any repairs.

Summary of Contents for 044166

Page 1: ...BENNING CC 4 1 CC 4 2 Operating manual Translation of the German original version 5186 07 2021 en...

Page 2: ...ll rights reserved This document particularly all of the contents texts photographs and graphics that it contains are protected by copyright No part of this documentation or the associated contents ma...

Page 3: ...e of delivery 12 4 Device description 13 4 1 Device structure 13 4 2 Functions 14 5 Operation 16 5 1 Requirements for measuring 16 5 2 Measuring with a multimeter 17 5 3 Measuring with the BENNING IT...

Page 4: ...Table of figures Table of figures Figure 1 BENNING CC 4 1 CC 4 2 device structure 13 5186 07 2021 en BENNING CC 4 1 CC 4 2 4...

Page 5: ...e 9 Table 3 Symbols used in the operating manual 9 Table 4 Electrical specifications 14 Table 5 Measuring accuracy BENNING CC 4 1 14 Table 6 Measuring accuracy BENNING CC 4 2 15 Table 7 Maintenance sc...

Page 6: ...on depending on the device e g brochures technical reports FAQs 1 1 General notes Target group This operating manual is intended for the following groups of people Qualified electricians and electrote...

Page 7: ...7 Trademarks All trade marks that are used are the property of their respective owners even if they are not separately marked as such 1 2 History Release number Amendments 07 2021 Initial release Tabl...

Page 8: ...le or deadly injuries will occur WARNING Hazard to humans If you do not pay attention to this warning irreversible or deadly injuries could occur CAUTION Minor hazard to humans If you do not pay atten...

Page 9: ...tribution circuit of the low voltage mains installation of a building The device complies with EU directives At the end of product life dispose of the unserviceable device via appropriate collecting f...

Page 10: ...ue to force majeure If any prescribed services are not performed regularly or not on time according to manufacturer specifications during the warranty period a decision about a warranty claim can only...

Page 11: ...recognisable consequences of prolonged storage under inadmissible conditions The device shows recognisable consequences of extraordinary stress due to transport 2 5 Special types of risks DANGER Bare...

Page 12: ...cope of delivery 5186 07 2021 en BENNING CC 4 1 CC 4 2 12 3 Scope of delivery The scope of delivery of the device includes the following components 1 x BENNING CC 4 1 or BENNING CC 4 2 current clamp a...

Page 13: ...3 4 6 5 7 BENNING CC 4 1 BENNING CC 4 2 Figure 1 BENNING CC 4 1 CC 4 2 device structure 1 Measuring clamp for clamping the conductor 2 Housing with labelling field 3 Current clamp bulge protection ag...

Page 14: ...at IDC 30 A Table 4 Electrical specifications Measuring accuracy The measuring accuracy is specified as the relative part of the measured value output current The specified measuring accuracy applies...

Page 15: ...00 mA Measured value Output Measuring accuracy1 Phase error 0 2 10 A 0 2 10 mA 2 5 Not specified 10 50 A 10 50 mA 2 0 3 0 50 200 A 50 200 mA 1 5 1 7 200 1 000 A 200 1 000 mA 0 9 0 9 1 000 1 200 A 1 00...

Page 16: ...ductor with the device until you have connected the device to a multimeter or a BENNING IT 200 installation tester Please observe the information regarding measuring accuracy page 14 Please consider s...

Page 17: ...lamp the live conductor with the measuring clamp 5 Read the current value on the multimeter 6 Convert the read value to the actually measured current value taking into account the conversion factor Co...

Page 18: ...ularly as needed Cleaning the device page 18 Every 12 months Calibrating the device page 18 Table 7 Maintenance schedule 6 2 Cleaning the device Clean the device regularly and as the need arises Requi...

Page 19: ...th x width x height 220 mm x 120 mm x 48 mm Max clamp opening 52 mm Max conductor diameter 50 mm Weight approx 0 6 kg Outputs 4 mm safety connectors 4 mm safety jacks Length of connecting cable 1 5 m...

Page 20: ...nd environmental protection 5186 07 2021 en BENNING CC 4 1 CC 4 2 20 8 Disposal and environmental protection At the end of product life dispose of the unserviceable device via appropriate collecting f...

Page 21: ...Intended use 10 M Maintenance 18 Maintenance schedule 18 Manufacturer 2 Measuring With a multimeter 17 With the BENNING IT 200 installation tester 17 N Non discrimination 2 P Purpose of the operating...

Page 22: ...g Subject to technical changes No liability accepted for printing errors BENNING Elektrotechnik und Elektronik GmbH Co KG M nsterstra e 135 137 D 46397 Bocholt Phone 49 2871 93 0 Fax 49 2871 93 429 In...

Reviews: