BENNING MA 4 measuring adapter
7
6.1.3. R
Insu
2 (sec.-PE)
Portable test sample
Connect the CEE connector of the test sample to the
CEE socket of the
measuring adapter
.
Connect the test probe to the bridged secondary side of
the device.
Start the R
Insu
measurement on your appliance tester.
As a result, you will obtain the measured R
Insu
value of the test
sample.
The insulating resistance is measured between the PE of the test
socket and the secondary side (probe).
Connection diagram
Circuit diagram
6.1.4. R
Insu
3 (LN-sec.)
Portable test sample
Connect the CEE connector of the test sample to the
CEE socket of the
measuring adapter
.
Connect the test probe to the bridged secondary side
of the device.
Start the R
Insu
measurement on your appliance tester.
As a result, you will obtain the measured R
Insu
value of the test
sample.
The insulating resistance is measured between the bridged LN
conductor and the secondary side (probe).
Connection diagram