- 5 -
Lp
A
sound pressure level
dB
54,7 ± 3,2
Required chimney draught
mbar
0,05
–
0,08
0,05
–
0,09
0,05
–
0,10
Boiler connections: - heating water
Js
G 1”
-
return water
Js
G 1”
Connection voltage
1 PEN 230V / 16A / ~ 50 Hz
Maximum electrical input power
W
395
429
Electrical rating
IP 20
Chart 2 Thermal-technical parameters of the boilers
Boiler type
BENEKOV
K14
BENEKOV
K20
BENEKOV
K25
Rated output
kW
15
20
25
Adjustable output
kW
4,5
– 15
6
– 20
7,5
– 25
Fuel consumption
kg . hr
-1
1,0
– 3,2
1,3
– 4,5
1,7
– 5,8
Output in inhibition mode
kW
1
1
1
Fuel consumption during inhibition
kg . hr
-1
0,25
0,25
0,25
Burning time at rated output and full fuel
store
hr
40
28
22
Boiler class according to EN 303-5
5
5
5
Eco design
Yes
Yes
Yes
Flue gas temperature
-
at rated output
°C
115
135
150
-
at minimum output
°C
90
90
90
Efficiency at rated output
%
91,3
90,4
89,5
Efficiency at minimum output
%
88,1
89,1
90,0
Mass flow rate of flue gases at exit point
-
at rated output
kg . s
-1
0,007
0,008
0,013
-
at minimum output
kg . s
-1
0,003
0,004
0,005
Electrical input power at rated output
W
45
55
64
Electrical input power at minimum output
W
29
29
29
Electrical input power in STAND BY mode
W
3
3
3
3. Boiler fuel specifications
Chart 3 specifies required (warrantied) types of fuel for BENEKOV K14, K20 and K25 boilers:
Chart 3 Required fuels
Fuel type according
to EN 303-5
C1
– wooden pellets
Grain (average)
[mm]
6 - 8
Length
[mm]
max. 30
Bulk density
[kg/m
3
]
600 - 650
Water content
[%]
max. 12
Ash content
[%]
max. 1,5
Calorific value
[MJ.kg
-1
]
min. 17
WARNING! Poor fuel quality can significantly affect the performance and emission parameters
of the boiler.
The pellets must meet the requirements of standard EN ISO 17225-2 Solid biofuels
– Specification and
fuel grades
– Part 2: Sorted wooden pellets.
Summary of Contents for K14
Page 1: ...BOILER OPERATION AND INSTALLATION GUIDE BENEKOV K14 BENEKOV K20 BENEKOV K25 ...
Page 9: ... 9 Fig 3 BENEKOV K14 boiler basic dimensions ...
Page 10: ... 10 Fig 4 BENEKOV K20 and K25 boiler dimensions ...
Page 17: ... 17 Fig 7 Position of the K14 boiler in a boiler room ...
Page 33: ... 33 Fig 17 Diagram of electrical connection of XS20 burner of the K14 boiler ...
Page 34: ... 34 Fig 18 Diagram of electrical connection of XS26 burner of the K20 and K25 boilers ...