- 16 -
F) machinery
CSN EN 614-1 + A1: 2009
Safety of machinery - Ergonomic design principles - Part 1: Terminology and
general principles
ČSN EN 953 + A1: 2009
Safety of machinery - Protective covers - General requirements for the
construction and manufacture of fixed and movable guards
EN 1037 + A1: 2008
Safety of machinery - Prevention of unexpected start-up
ISO 12100: 2011
Safety of machinery - Basic concepts, general principles for construction
ISO 13857: 2008
Safety of machinery - Safe distances to prevent reach of dangerous places
by upper and lower limbs
5.2. Boiler location options
Boiler location in regards to the electric supply:
•
the boiler must be positioned so the plug in the socket (230V / 50Hz) is always accessible.
•
the boiler needs to be always connected to the mains by a flexible secure lead with a standardized plug.
•
protection against electric shock (including earth connection of individual metal parts) must be ensured in
accordance with valid regulations
ČSN EN (see chapter 5.1.)
Boiler location in regards to fire regulations:
1. Location on a base made of non-flammable material
•
Place the boiler on a non-flammable heat insulating mat which exceeds the size of the boiler by 20
mm on each side.
•
If the boiler is located in a basement it is recommended to place it on a structure at least 50 mm high
off the floor level. The boiler must be positioned horizontally.
2. Safe distance from flammable materials
•
The smallest permissible distance of the external contours of the boiler and the smoke flue from any
flammable materials (see more specifications
in ČSN EN 13 501-1 + A1: 2010) is 400 mm during
installation as well as during the operation of the boiler.
Summary of Contents for K14
Page 1: ...BOILER OPERATION AND INSTALLATION GUIDE BENEKOV K14 BENEKOV K20 BENEKOV K25 ...
Page 9: ... 9 Fig 3 BENEKOV K14 boiler basic dimensions ...
Page 10: ... 10 Fig 4 BENEKOV K20 and K25 boiler dimensions ...
Page 17: ... 17 Fig 7 Position of the K14 boiler in a boiler room ...
Page 33: ... 33 Fig 17 Diagram of electrical connection of XS20 burner of the K14 boiler ...
Page 34: ... 34 Fig 18 Diagram of electrical connection of XS26 burner of the K20 and K25 boilers ...