BENE T-Meeting Safety And Operating Instructions Manual Download Page 1

http://bene.com/liftdesk

LIFT DESK. T-MEETING

EN

 

SAFETY AND OPERATING INSTRUCTIONS

NOTE

 

Please read all instructions carefully before operating the system. Keep instruction manualfor 
further reference. This document is alternative available on the official Bene - homepage. 
(www.bene.com)

Summary of Contents for T-Meeting

Page 1: ...K T MEETING EN SAFETY AND OPERATING INSTRUCTIONS NOTE Please read all instructions carefully before operating the system Keep instruction manualfor further reference This document is alternative available on the official Bene homepage www bene com ...

Page 2: ...lay of the table top position 12 Manual control Manual reset 13 Manual control Keylock 14 Manual control Pedestal stop Shelf stop 15 Manual control Pedestal stop Shelf stop Changing display from cm to inches 16 Manual control Reset to factory defaults 17 Manual control Error messages on the manual controller display 18 Manual control Click codes 21 Levelling Reset 22 Technical data 23 Cleaning ins...

Page 3: ...3 PRODUCT OVERVIEW STANDARD TABLE SIZES 2000 1100 2200 1100 2400 1200 TABLETOP OPTIONS rectangular rounded rectangular oval boat shaped ...

Page 4: ...stacle is encountered or if there is a functional fault stop the adjustment immediately 6 Make sure adjacent objects are placed at a minimum distance of 25 mm to prevent them from being squeezed or sheared 7 Ensure that the safety distances are 25 mm for movable parts this also applies for organisational elements which are fitted above or underneath the furniture mounted to adjoining walls or buil...

Page 5: ... mental abilities or failing experience and or knowledge unless they are supervised by a person responsible for their safety or received instructions about how to use the appli ance Children should be supervised in order to make sure that they do not play with the appliance 16 The manufacturer assumes no liability for damage resulting from improper use 17 Connection plug boards must be fixed prope...

Page 6: ... so as to avoid any risk 21 Do not spill liquids into the control unit or power supply unit as this could cause electrical shock or short circuits 22 The operation of the control mechanism and the power supply unit requires a minimum of 5 C and a maximum temperature of 40 C 23 For the above reasons do not install the control unit above or in front of heat sources e g radiators at places exposed to...

Page 7: ...Warning During all reset procedures section 5 the collision protection is not active Please take care to avoid possible danger of crushing Please note If the product is visibly damaged it must not be installed or used further 24 After 2 minutes of continuous operation the system automatically shuts itself off and cannot be used for an additional 18 minutes This keeps the motor from overheating 25 ...

Page 8: ...s and their negative health impact at the office workplace These standards and recommendations are based on findings relating to an incorrect and tense sitting posture which limits performance and produces long term physical damage over time Sitting with a hunched back doubles the burden 200 on the vertebral disks compared to standing up 100 100 200 Source Wilkhahn ...

Page 9: ...ment referred to the price list mit folgenden EU Richtlinien bzw Normen übereinstimmt meets the requirements of the following EC directives and standard s Maschinenrichtlinie 2006 42 EG mit Änderungen Machinery directive 2006 42 EG including amendments Richtlinie elektromagnetische Verträglichkeit 2004 108 EG mit Änderungen EMC directive 2004 108 EG including amendments Niederspannungsrichtlinie 2...

Page 10: ...OL GENERAL INFORMATION PRO MANUAL CONTROL LIGHT MANUAL CONTROL Raise table top Raise table top 2 Motor group Lower table top Pedestal Lower table top Lower table top 2 Motor group Raise table top Reset Memory button Ergoflex Memory position buttons 1 4 Info Log ...

Page 11: ...ition is shown on the display 2 Press the memory button Ergoflex Info Container Reset Log 2 S 3 4 The display will read S 3 Press the desired memory button 1 4 Ergoflex Info Container Reset Log 1 2 S 3 4 The display will read S 2 This saves the table top position under the selected memory position key There is an audible double click and after 2 seconds the sa ved table top position is displayed A...

Page 12: ...osition 1 Press the memory button Ergoflex Info Container Reset Log 2 S 3 4 The display will read S 2 Press the lower table top button for about 10 seconds 4 The display will begin to blink 3 Set the desired values for the table top position with the raise table top and lower table top buttons Ergoflex Info Container Reset Log 1 2 S 3 4 Ergoflex Info Container Reset Log 1 2 S 3 4 4 Press the memor...

Page 13: ...le of the shifting area Ergoflex Info Container Reset Log 2 S 3 4 1 3Release the button s The electrically height adjustable workstation can now be used again normally 2 1 Simultaneously press and hold the lower table top and raise table top buttons for about 5 seconds until the tabletop moves in the middle of the shifting area 2 2 Simultaneously press and hold the lower table top and raise table ...

Page 14: ...eset Log 2 S 3 4 Ergoflex Info Container Reset Log 1 2 S 3 4 UNLOCK Press the S button and then press the lower table top 2nd motor group button Ergoflex Info Container Reset Log 1 2 S 3 4 Ergofl Info Container Reset Log 1 2 S 3 Note If the keylock is activated it remains activated even when the power cable is removed from the power source and is plugged in later at any time Ergoflex Info Containe...

Page 15: ...ing ACTIVATE POSITION 1 Position the table top where you want to set the new pedestal stop or shelf stop position Use the lower table position or raise table position buttons to maneuver the table into position 4 Ergoflex Info Log 3 4 2 1 Press the S button Ergoflex Info Container Reset Log 1 2 S 3 4 The display will read S 2 2 Press at the same time briefly the lower table position and raise tabl...

Page 16: ... 2 Press the S button Ergoflex Info Container Reset Log 1 2 S 3 4 The controller is now set to cm or inches DEACTIVATE POSITION Deactivation is done in the same manner as activation except for the last step 3 2Within 5 seconds press the lower table position button and hold it for at least 5 maximum 10 seconds 4 An audible single click after pressure of the key in the motor control indicates that t...

Page 17: ...Reset Log 1 2 S 3 4 Ergoflex Info Container Reset Log 1 2 S 3 4 Ergoflex Info Log S 3 4 After releasing the buttons the display will read S 1 or S 5 2 Press and hold the raise table top button until the dis play reads S 0 4 The display will read S 0 3 Press the memory button Ergoflex Info Container Reset Log 1 2 S 3 4 The controller is then reset to its factory defaults Ergoflex Info Container Res...

Page 18: ... 3 Defect channel 1 4 Unplug the motor control 5 Repair the external short circuit or plug the correct motor to the affected connector 6 Begin operating the motor control again Defect channel 2 Defect channel 3 Overload motor M1 7 Remove the obstacle from the path of movement 8 Table overloaded Remove the weight from the table 9 Contact customer service Overload motor M2 Overload motor M3 Overload...

Page 19: ...m the table 3 Perform a reset if the error continues to be displayed after the reset then contact customer service Synchronisation of motor group 2 not pos sible Voltage too high 4 Unplug the power cable and contact customer service Change in motor configuration 5 See the Pedestal stop Shelf stop section Sensor configuration changed Unplug the motor control and wait for at least 5 seconds Take the...

Page 20: ... drive positi on are not matching at the reset Internal error 5 Perform a reset 6 Unplug the power cable wait a few seconds and plug it back in 7 If this error occurs regularly unplug the power cable and contact customer service Note PowerFail Detection identifies power failures and saves all relevant data before voltage falls below a critical level In a few exceptional cases this save will not be...

Page 21: ...o be moved up down button and or memory buttons 2x far apart slow double click Reset mode The system is currently in reset mode This signal is always produced when the table should not be lowered in the reset direction up button and or memory buttons 3x close together quick triple click Sensor missing The crush protection sensor is not connected to the controller This signal is always produced whe...

Page 22: ...for the first time in order to operate the product For a table the reset causes all of the columns to be brought to the same level in the table s lowest position This ensures that the table top is positioned parallel with the ground The controller also saves the connected components in the standard configuration such as columns or a sensor After the reset configuration changes are detected and con...

Page 23: ...ence values Load Power consumption Stand by 0 100kg 0 5 watts h Upward lift 0kg 141 0 watts lift Upward lift 100kg 380 0 watts lift Carefully design the safety circuit Recommendation max 6 8 tables for one safety circuit Determined by on site technican The sound intensity level upon exercise of the electrical height adjustment of the table according to ÖNORM EN ISO 7779 Position Values in dB upwar...

Page 24: ...d open pored veneer appearance is ruined Furniture polishes available off the shelf can be used for closed pore lacquered surfaces beech and maple They fill the finest of scratches in the lacquer and cover them up relatively well An enhanced glossy appearance of the surface is difficult to prevent Never use polishes containing silicon caustic cleaning agents with ammonia DISPOSAL Instructions for ...

Page 25: ...25 NOTES ...

Page 26: ...26 NOTES ...

Page 27: ...27 NOTES ...

Page 28: ...cs to product recycling Bene considers ecology to be a central element of its responsible and stable corporate strategy Bene sees the legal regulations as minimum requirements and strives for better and more sustainable environmental protection throughout the group The Bene principle in environmental policy is Avoidance Minimisation Recycling Disposal LIFT DESK T MEETING WP_MB176_SB_EN 032018 TE ...

Reviews: