The Bendix

®

 DV‑2

 automatic reservoir drain valve ejects 

moisture and contaminants from the reservoir in which it 

is connected. It operates automatically and requires no 

manual assistance or control lines from other sources.

The automatic reservoir drain valve has a die cast 

aluminum body and cover, and is normally mounted either 

in the bottom of the reservoir – using the top port of the 

drain valve, or in the end of an end drain reservoir – using 

the side port of the valve.

The DV‑2 drain valve is also available with a heater and 

thermostat cast into the cover for vehicles operated in 

subfreezing temperatures. The heated DV‑2 valve is 

supplied in either a 12 or 24 volt model and in a bottom 

or  end  drain  configuration. A  1/4”  male  pipe  adapter  is 

supplied with all DV‑2 drain valves, end drain and bottom 

drain, both standard and heated. This adapter should be 

installed directly into the reservoir. Early versions included 

a filter screen in the adapter. The filter should be discarded. 

Later versions may have a standard pipe nipple instead 

of the adapter.

SD-03-2501

Bendix

®

 DV-2

 Automatic Reservoir Drain Valve

Standard Bendix

® 

DV-2

 

Drain Valve

DV-2 Drain Valve with Heater and Thermostat

Adapter

Body

Top Reservoir 

Port

Side 

Reservoir 

Port

Inlet & 

Exhaust 

Valve

Thermostat 

Housing

Heater Element

Cover

Exhaust Port

Wire Stem

Electrical Lead 

Wire

Valve 

Guide

Sealing 

Ring

DV-2 Drain Valve 

with Heater

Figure 1 – Bendix

®

 DV-2

 Drain Valves

Summary of Contents for DV-2

Page 1: ...es The heated DV 2 valve is supplied in either a 12 or 24 volt model and in a bottom or end drain configuration A 1 4 male pipe adapter is supplied with all DV 2 drain valves end drain and bottom drain both standard and heated This adapter should be installed directly into the reservoir Early versions included a filter screen in the adapter The filter should be discarded Later versions may have a ...

Page 2: ... parking brakes and always block the wheels Always wear personal protection equipment Stop the engine and remove the ignition key when working under or around the vehicle When working in the engine compartment the engine should be shut off and the ignition key should be removed Where circumstances require that the engine be in operation EXTREME CAUTION should be used to prevent personal injury res...

Page 3: ...d filter in the adapter which should be removed and discarded LEAKAGE TEST With system charged and pressure stabilized in system there should be no leaks at the drain valve exhaust A constant slight exhaust of air at the drain valve exhaust could be caused by excessive leakage in the air brake system or contamination If the drain valve continues to exhibit leakage at the exhaust after inspection a...

Page 4: ...e control or ignition switch Use an 8 amp fuse for one valve a 15 amp fuse for two valves and a 20 amp fuse for three valves All electrical connections must be waterproof CLEANING AND INSPECTION 1 Cleaning solvent may be used on metal parts Rubber parts should be wiped clean 2 Inspect all parts for wear or deterioration Discard the filter screen if present 3 Replace all parts not considered servic...

Reviews: