background image

9

Positioning

The appliance may be placed in any room, provided the
following precautions are taken.
The appliance expels hot, very moist air. The rest of the
house must be able to easily absorb this moisture.
Normally, absorption is only possible in houses where
there is very little humidity. Otherwise, the room must
have ventilation towards the outside; generally, an open
door or window is enough.

The capacity of the venting circuit must be at least 150
m

3

/hour. Check that the air inlet and outlet vents are

unobstructed.

The best way of evacuating the moisture is through a vent
hose to the outside of the building. Use the special 100
mm diameter flexible hose supplied with the appliance
connected to one of the air outlet vents with the collar
supplied. 
The unused outlets must be covered.
Never connect the air vent hose into an existing discharge
pipe or duct, as this could be dangerous, might disturb
neighbours and could cause the dryer to malfunction.

This product is supplied with a 2.50 metre vent hose,
although the maximum length of the vent hose may be:

4 metres with no bends, or 2 metres with 2 bends.

Advice

: If the hose is long and the room temperature low,

the moisture might condense to water inside the hose.

This is an unavoidable natural phenomenon.

To

prevent this water from lying in the hose or flowing back
into the tumble dryer, it is advisable to drill a small hole
(dia. 3 mm) in the lowest point of the hose and to place a
small container below it. (See picture, point A).

Connect the other end of the hose to an opening in a door
or window. Fit a suitable shield or point the  hose
downwards to prevent any rain water and wind from
getting in.
Rain and wind shields for placing over openings usually
consist of valves or movable flaps. Periodically check the
shield since strong winds and other factors (rust, dirt) can
sometimes prevent it from opening, so causing problems
with air venting.

If you use a rain shield, check that the openings in it are
large enough to allow air to escape. Openings which are
too small restrict the flow of air.

Problems can be encountered in rooms fitted with a very
powerful central extractor fan. If you find that drying
times are too long, switch off the extractor or close its
grille whilst the tumble dryer is in use.

A highly effective solution is to simply poke the vent hose
through a window or skylight. This might however cause
problems in winter because the dryer will draw in very
cold (and often also very damp) air through the open
window, so increasing drying times and leading to very
high energy consumption.

If the dryer is fitted next to kitchen units, make sure
that the vent hose is not squashed. If the hose is
partially squashed, drying efficiency wlll be reduced,
resulting in longer drying times and higher energy
consumption.

If the hose is completely squashed, the safety cut-outs
with which the machine is fitted may operate.

Condensation discharge through
the vent hose

Condensation may be discharged either through a vent
outlet provided at the back or through the left or right side
outlet.

The vent hose collar is
placed in the rear vent outlet.
Remove the collar by pulling
it out of the vent outlet.
Screw the collar to the vent
hose.
Fit the hose into the required
vent outlet, and place vent
covers provided over the
unused outlets.

The vent hose must not
contain more than two bends
when it is placed in position
for operation.

You should 

NOT 

connect

the flexible vent hose to, for
example, a chimney or flue
pipe designed to carry the
exhaust from a fuel burning
heating appliance.

P0330

Installation

A

P0751

P0279S

P0055

125993370.qxd  7/26/02  9:32 AM  Pagina  9

Summary of Contents for BTD 03

Page 1: ...TUMBLE DRYER BTD 03 OPERATING INSTALLATION INSTRUCTIONS 125993370...

Page 2: ...5 kg iron dry This appliance complies with the following E E C Directives 73 23 EEC of 19 2 73 Low Voltage Directive and subsequent modifications 89 336 EEC of 3 5 89 Electromagnetic Compatibility Di...

Page 3: ...as duvets and eiderdowns should be dried in large commercial machines because of their bulk check with the manufacturer of the item if it is suitable for drying in a domestic machine even if the dry...

Page 4: ...at a low temperature for synthetic fabrics To set the machine to the selected time turn the dial clockwise until the time you want coincides exactly with the pointer NEVER attempt to turn the dial in...

Page 5: ...large quilts for example The laundry must be suitably spun in your washing machine before being placed in the tumble dryer 500rpm minimum Drying times vary according to The type of laundry The size of...

Page 6: ...owing Particularly delicate items such as net curtains woollen silk fabrics with metal trim nylon tights bulky materials such as anoraks blankets eiderdowns sleeping bags feather quilts and any items...

Page 7: ...door is open The plug is not fitted into the wall socket There is no electricity supply from the wall socket The time selector dial is not set correctly The dryer does not dry properly The filter is...

Page 8: ...rcial environment plus those which are subject to rental agreements Products of Bendix manufacture which are NOT marketed by Bendix European guarantee If you should move to another country within Euro...

Page 9: ...ver openings usually consist of valves or movable flaps Periodically check the shield since strong winds and other factors rust dirt can sometimes prevent it from opening so causing problems with air...

Page 10: ...ration and noise to a minimum when the dryer is in use Door reversal To make it easier to load or unload the laundry the door can be reversed This operation must be carried out by qualified personnel...

Page 11: ...which is marked with the letter E or the earth symbol or coloured green and yellow Connect the blue neutral wire to the terminal in the plug which is marked with the letter N or coloured black Connect...

Page 12: ...Electrolux 55 77High Street Slough Berkshire SL1 1DZ Consumer care telephone number 08705 950950 Electrolux plc 2002...

Reviews: