Technical data VMD460-NA
81
VMD460-NA_D00001_05_M_XXEN/01.2020
8.1 Standards, approvals and certifications
The VMD460-NA has been certified by Bureau Veritas.
8.2 Ordering details
Standard/application guide
Explanation
VDE-AR-N 4105:2018-09
(replaces VDE-AR-N4105:2011-08)
Generators connected to the low-voltage distribution network –
Technical requirements for the connection to and parallel operation with low-volt-
age distribution networks
VDE-AR-N 4105:2011-08
Generators connected to the low-voltage distribution network –
Technical requirements for the connection to and parallel operation with low-volt-
age distribution networks
VDE-AR-N 4110:2018-11 (replaces BDEW guideline)
Technical requirements for the connection and operation of customer installations
to the medium voltage network (TCR medium voltage)
BDEW technical guideline 2008 with amendments
until 01.2013
Technical guideline Generating plants connected to the medium-voltage network;
Bundesverband der Energie- und Wasserwirtschaft e.V., Berlin, Juni 2008 (German
association of energy and water industries)
DIN V VDE V 0126-1-1:2006-02/A1:2012-02
Automatic disconnection device between a generator and the public low-voltage
grid
CEI 0-21(:2012-06, :V1:2012-12, :V2:2013-12,
:2014-09, :V1:2014-12; 2016-07, V1:2017-07)
Regola tecnica di riferimento per la connessione di utenti attivi e passivi alle reti BT
delle imprese distributrici di energia elettrica) CEI 0-21:2012-06; CEI 0-21
V1:2012-12; CEI 0-21 V2:2013-12; 2016-07; V1:2017-07
C10/11:2012-06
Prescriptions techniques spécifiques de raccordement d'installations de produc-
tion décentralisée fonctionnant en parallèle sur le réseau de distribution; June
2012
G98/1-4:2019
(replaces G83/2:2012)
Engineering Recommendation G98 - Requirements for the connection of Fully
Type Tested Micro-generators (up to and including 16 A per phase) in parallel with
public Low Voltage Distribution Networks on or after 27 April 2019
G83/2:2012 and G59/3:2013
Engineering Recommendation G83 - Recommendations for the Connection of Type
Tested Small-scale Embedded Generators (Up to 16A per Phase) in Parallel with
Low-Voltage Distribution Systems
G99/1-4:2019
(replaces G59/2:2010, -1:2011 and G99/3:2013)
Engineering Recommendation G99 - Requirements for the connection of genera-
tion equipment in parallel with public distribution networks on or after 27 April
2019
G59/3:2013
Engineering Recommendation G59 - Recommendations for the Connection of
Generating Plant to the Distribution Systems of Licensed Distribution Network
Operators
G59/2(:2010, -1:2011)
UL
File No. E173157
Device type
Nominal voltage
U
n
Supply voltage
U
s
Art. No.
VMD460-NA-D-2
3(N) AC 400/230 V; 50 Hz
AC/DC 100…240 V; DC 50/60 Hz
B93010045
Mounting clip for screw mounting (1 piece per device, accessories)
B98060008