Belshaw Bros., Inc.
www.belshaw.com
Phone 206-322-5474
Fax 206-322-5425
20
MN-1012EN
Donut Robot Mark II OM
WARNING
If you allow shortening to overflow the
container, the shortening could burn you, and
it will get on the floor, possibly causing slips,
falls, injury, or even death. If shortening does
get on the floor, thoroughly clean and dry the
floor right away.
3. When the shortening stops flowing, tilt up
the side of the kettle opposite the siphon.
Place a wedge under the side of the kettle to
hold it up. The remaining shortening will
now flow toward the siphon.
4. Set aside the container of shortening.
5. Remove the filter assembly.
6. Place a different container under the valve
assembly and start the siphon again. Drain
the remaining shortening and discard it; it
will be full of sediment.
Cleaning
1. Remove the siphon from the Donut Robot.
2. Squeeze the bulb several times to expel
shortening from the siphon.
3. Wipe the siphon clean and hang it with the
bulb side up so any remaining shortening
will drain. Place a pan under the siphon to
collect the shortening.
4. Rinse the filter bag and hang it to dry. You
may launder it as needed.
WARNING
After washing, be sure the Filter Flo Siphon is
completely dry before using it again.
Moisture will cause hot shortening to spatter,
which may cause serious injury.