SAFETY PRECAUTIONS
CAUTION
9. Close the water main valve and turn off the main switch upon completion of work
Be sure to close the water main valve and the main switch at the end of each work day to prevent water
leakage from occurring.
5. Keep your eyes on the patient during operation.
• Confirm that the patient is seated in the proper position. Keep your eyes on the patient during the operation.
• Pay special attention to surroundings at automatic operation of the dental treatment table. Damage to the backrest,
stool or Doctor's table may occur.
6. Pay attention during movement of the Doctor's table
• Pay attention to surroundings when you move the Doctor's table. Injury by the tips of handpieces, etc.,
may occur.
• Be sure to move the Doctor's table by holding the handle of the unit.
• Be sure to move up & down the Doctor's table by releasing the balance arm brake of the unit.
If the brake is not released, the table may drop resulting in defective function.
8. Immediately wipe off drug solution when it comes into contact with this unit
Should drug solution or water comes into contact with this unit, immediately wipe it off with a dry soft towel,
etc. This could result in defective function or electric leakage as well as spotting or rusting.
10. Be sure to operate switches with your hands
Be sure to operate switches with your hands, except the foot controller, which is operated with your foot.
Operation with body parts other than hands may cause damage or incorrect operation.
7. Do not smack or rub this product
Do not smack or rub this product forcefully. This could cause damage to covers or defective function.
11. Be careful not to heat an empty water heater
Exercise caution as heating of an empty water heater may result in burning of the heater, leading to fire.
12. Precautions for sterilization
Do not sterilize besides the procedures that we provide. This could cause damage to the unit.
14. Set the pressure of the water tank at 200 kPa or less
Adjust the air supply pressure for the water tank to 200 kPa or less. An excessively high pressure may cause
damage to the water tank.
16. Read the documents accompanying the various pieces of equipment
Before use, be sure to carefully read the package inserts and Instruction Manuals accompanying the various
pieces of equipment to ensure proper use.
15. Do not use water other than purified water, distilled water or pure water for the water tank
• The water tank is intended only for use with purified water, distilled water and pure water.
• Do not use mouthwash or electrolyzed water, such as ConCool or povidone iodine, as they may cause
clogged tubing or affect internal valves and equipment.
13. Practice of flush out
Practice the flush out of water retained in the unit before the start of clinical practice at the beginning of each
work day to maintain the quality of water for dental treatment and ensure a steady supply of water to handpieces.
Refer to the procedure for flush out.
17. About LED light of the panorama size film viewer (Optional)
• Your eyes could be dazzled by LED light not only under dark environment but also under normal environment.
Be careful about the brightness of the ambient.
• Use of controls or adjustments or performance of procedures other than those specified herein may result in
hazardous radiation exposure.