No. Item Frequency Inspection method
and diagnosis
Influence if inspection
not conducted
Maintenance required in case
of nonconformity
20
21
22
23
Care
Exterior
Chemical, filthy water and
so forth shall not be found
(attached or remaining) on
the product exterior.
Discoloration and
deterioration to the
exterior, and corrosion
and rusting to metallic
components may arise.
Execute wiping in accordance
with "Method for care" described
in the instruction manual.
After
closing
Care
Solid
collector
Clean the filter of the solid
collector.
Vacuum suction will
become weak.
Clean the filter in accordance with
"Method for care" described in the
instruction manual.
After
closing
Care
Drain
valve
Drain the water from
the air filter drain valve.
Water may enter the air
line, and equipment failure
may arise.
Drain the water from the air filter
in accordance with "Method for
care" described in the instruction
manual.
Once
every
week
Care
Oil mist
separator
Sponge of oil mist separator
shall not saturate with oil.
Normal output will not be
produced due to inferior
handpiece exhaust.
Discharge the oil in accordance
with "Method for care" described
in the instruction manual.
Once
every
month
Parts Description
Vacuum handpiece body
Saliva ejector handpiece body
Foot controller
Water supply hose
Drain hose
Air supply hose
Electric wiring of moving part
Standard
Lifetime
No.
3 years
1
2
3 years
3
5 years
3 years
3
4
4
5
3 years
No
.
Parts Description
1
2
Parts Description
Standard
Lifetime
No.
3 years
8
9
3 years
10
5 years
5 years
11
12
3 years
Regulator
Valves
Switches
Film viewer body part
Pressure gauge
Arm section of moving part
Control PCBs.
6
3 years
13
7 years
7
5 years
14
5 years
Valve for vacuum handpiece body
Vacuum tip
Handpiece tubings
Vacuum hose
Saliva ejector hose
8
No
.
Parts Description
6
7
Filter for oil mist separator
Filter (Air & Water)
O-ring, Packing, Diaphragm
5
MAINTENANCE AND INSPECTION
Guide for Periodical Check-up
Some parts and components of the products are degraded or deteriorated depending on the frequency of use.
Annual check-up and maintenance, as well as replacement of consumable parts, are required.
The required parts (including consumable parts) are listed below. It may be different from the following list
depending on the option of the unit.
For check-up and repair, call a technician of our authorized dealer.
Execute the maintenance in accordance with this instruction manual and operating manual attached
to each individual equipment ( Dental light, Handpiece, etc..) .
Failure to maintain this product may lead to physical injury or property damage.
Parts and components that require periodical check-up
Consumable parts
WARNING
4
1
Summary of Contents for CREDIA G1
Page 2: ......