SAFETY PRECAUTIONS
WARNING
10. Do not place objects weighing 1.5 kg or more on the Sub tray
• Failure to maintain this product may lead to physical injury or property damage.
• Refer to the section of maintenance.
11. Be sure to use the mirror cover
• Be sure to use the mirror cover of the dental light when the light is turned on. Direct contact with lamps
may cause burns.
• See the Instruction Manual of the dental light for further information.
12. Be sure to turn off the power when replacing lamps
9. Ensure the maintenance of this product
Do not place objects weighing 1.5 kilograms or more on the Sub tray. This could cause damage to the Doctor's
table, defective function or accidents.
• Be sure to turn off the power when replacing the dental light. This could result in electric shock.
• Use only dedicated halogen lamps.
• Immediately after a halogen lamp has burnt out, the lamp and the lamp holder are still hot. Replace the
lamp after they cool down.
• Do not touch halogen lamps with bare hands.
• See the Instruction Manual of the dental light for further information.
13. Immediately wipe off any water spills or leakage on the
fl
oor
Immediately wipe of
f any water spills or leakage on the floo
r
. Decreased strength of the floor may lead
to physical injury including fall, or property damage.
14. Use with caution on patients with a cardiac pacemaker
Use this product with extreme caution on patients with a cardiac pacemaker. In the case of any abnormalities in
patients during use, immediately turn off this product and discontinue use.
CAUTION
1. Only experienced personnel should use this product
Only dentists or other dental professionals should use this product.
2. Confirm safety before use.
Before use, c
onfir
m that the parts are correctly and safely operating and that there are no obstacles around this
product.
Keep your eyes on patients (especially, children) so that mischief or inadvertent operation of equipment will
not lead to unexpected accidents.
3. Pay attention to patients and children
-2-
During operation, repair and maintenance are prohibited.
15. Prohibition of maintenance
16. Prohibition of using this equipment adjacent to or stacked with other electronic equipment
Use of this equipment adjacent to or stacked with other equipment should be avoided because it could result
in improper operation. If such use is necessary, this equipment and the other equipment should be observed to
verify that they are operating normally.
17. Prohibition of placing portable RF communications equipment adjacent to this product
Portable RF communications equipment (including peripherals such as antenna cablesand external antennas)
should be used no closer than 30 cm (12 inches) to any part of the CLESTA
Ⅱ
, including cables
specified
by the
manufacturer. Otherwise, degradation of the performance of this euipment could result.