1. OVERVIEW AND MAJOR PARTS 

Fig.1-1

    Overview and Major Parts

Cupfiller Nozzle
Cupfiller Base
Bowl Flush Nozzle
Spittoon Bowl
Solid Collector
Cuspidor Unit Control Panel
Assistant Instruments Holder 
(With Membrane Switch)
Vacuum Handpiece

Assistant Side Syringe

14

15

25

16

17

19

18

22

23

24

20

21

1

2

3

4

7

8
9

10
11

12

13

5

6

W

A

26

Handle
   Right Hand Side : Standard
   Left Hand Side : Option

Rod

Dental Size Film Viewer
Handpiece Rest
Sub Tray Holder
Foot Controller
Dental Light
Handpieces (Micromotor, Air Turbine/Motor,
         Scaler and etc.) Manufacturers recommend
         to use the handpieces with CE markings

Saliva Ejector Handpiece
Assistant Holder Arm
Cuspidor Top
Cuspidor Body
Light Pole
First Arm (Horizontal Arm)
Balance Arm

T

able Housing

Main Control Panel
    Right Hand Side : Standard
    Left Hand Side : Option

9

13

11

12

15

16

10

8

14

7

2

6

1

4

3

5

18

22

26

17

23

21

25

20

24

19

-6-

Summary of Contents for Clesta II

Page 1: ...before operating the unit After the installation is completed le this manual and refer back to it for future maintenance 0197 If you have any questions about this Manual or this product please contac...

Page 2: ......

Page 3: ...N 18 4 SAFETY LOCK DEVICE 18 5 CARE AND MAINTENANCE 19 6 MAINTANANCE AND INSPECTION 6 1 GUIDELINE FOR DAILY MAINTENANCE AND INSPECTION 25 MAINTENANCE AND INSPECTION BY USER 6 2 GUIDELINE FOR PERIODICA...

Page 4: ......

Page 5: ...dental light Handpieces that can be used with this product Use the Handpieces described on page 30 Chair that can be used with this product Use the Chair described on page 30 Dental Light that can be...

Page 6: ...s SYMBOLS In this manual on the labels or on the control panel of CLESTA ROD TYPE following symbols are used Confirm the meaning of each symbol Serial number Reference number 1 The color of black part...

Page 7: ...lush About 5 minutes for cleaning water in cupfiller line Flushout procedure Handpiece line Pick up one handpiece out of the holder and hold it over the cuspidor bowl with the turbine kept as it is an...

Page 8: ...turn off the main switch upon completion of work or during work breaks This prevents incorrect operation due to accidental contact and associated hazards 4 Do not place an undue load on the arm Do no...

Page 9: ...ients with a cardiac pacemaker Use this product with extreme caution on patients with a cardiac pacemaker In the case of any abnormalities in patients during use immediately turn off this product and...

Page 10: ...sensor may react to hands Resulting water spill 12 Immediately wipe off drug solution when it comes into contact with this unit Should drug solution or water comes into contact with this unit immedia...

Page 11: ...of ush out Practice the ush out of water retained in the unit before the start of clinical practice at the beginning of each work day to maintain the quality of water for dental treatment and ensure...

Page 12: ...r check valve The water unit is intended for use with tap water Caution should be exercised as the use of water other than tap water water through a sterilizer of water systems etc may result in failu...

Page 13: ...andle Right Hand Side Standard Left Hand Side Option Rod Dental Size Film Viewer Handpiece Rest Sub Tray Holder Foot Controller Dental Light Handpieces Micromotor Air Turbine Motor Scaler and etc Manu...

Page 14: ...700 21 28 890 274 9 0 517 9 0 90 1 3 8 441 184 569 60 60 5 651 489 737 50 8 42 7 600 750 187 723 294 666 194 90 549 723 294 666 194 90 549 Fig 2 1 Dimensions Chair Mount Type Pedestal Type 7 10 to 95...

Page 15: ...icator MAIN LOCK 1 2 0 LP 2 1 6 4 3 7 5 MAIN LOCK 1 2 0 LP F 2 1 4 3 5 16 15 13 11 7 14 6 9 10 12 8 Cup ller Switch Fig 3 5 Momentarily press the cup ller switch water will come out from the cup ller...

Page 16: ...outh rinsing position and stops automatically Momentarily press LP switch again the backrest returns to the previous treatment position and stops automatically d Emergency Stop Safety Stop During auto...

Page 17: ...the xed rotation speed indicated on the indicator Dental Light ON OFF Switch Fig 3 14 Switch for on off the dental light Fig 3 12 Electric Motor Speed Set Switch Fig 3 13 Electric Motor Rotation Direc...

Page 18: ...memory 0 Switch 1 Switch 2 Switch LP Switch 0 1 2 2 Preset time setting Store Switch Function Switch Decrease Switch Increase Switch 3 Preset time operation 4 Cancel the timer during time countdown 0...

Page 19: ...times and momentarily press the increase switch Function Switch Decrease Switch Increase Switch 1 Short time ush out Momentarily press the function switch three times and momentarily press the decreas...

Page 20: ...ctronic sound for timer Electronic sound for timer can be changed Momentarily press the function switch six times Momentarily press one of chair auto mode switch 0 1 2 LP then the new electronic sound...

Page 21: ...drive air pressure is shown in the pressure gauge Fig 3 16 Doctor Table Section Control Knobs 5 Balance Arm Air Brake Fig 3 17 When the master switch is ON the balance arm is locked by the air brake...

Page 22: ...witch is located on the cuspidor unit control panel Turn on the water heater switch and the cup ller water will warm up C Service Water Outlet Fig 3 19 The service water outlet provides a quick connec...

Page 23: ...ls up the cup and stops automatically When cup ller starts the bowl ush also starts and will run for about 6 sec and it stops automatically While lling the cup momentarily press the cup ller switch an...

Page 24: ...or electrolyzed water as they may cause clogged tubing or affect internal valves and equipment Adjust the air supply pressure for the water tank to 200 kPa or less An excessively high pressure may ca...

Page 25: ...pedal further to the right The speed control by the foot control is within the limits of the electric motor speed setting E Coolant Water Switch Electric Motor Rotation Direction Switch Optional The...

Page 26: ...Bowl A Detach the drain cap and clean the basket strainer Remove the cup ller base and clean it Turn the bowl ush nozzle counterclockwise avoiding the clash with the cuspidor bowl Fig 5 1 B Turn the c...

Page 27: ...clean and sterilize it at the end of each work day Recommended cleaner Orotol Plus made by DURR 5 Vacuum hose and saliva ejector hose are detachable from the cuspidor unit Fig 5 6 Turn the hose conne...

Page 28: ...each Fig 5 10 B Check whether contamination is removed or not after cleaning Continue the cleaning if contamination is remained C Immersed with an alkaline disinfection or detergent for 5 minutes We r...

Page 29: ...Insert the handpiece in a sterilization pouch and seal it B Autoclave for 3 min at 134 and dry for 15 min Sterilization with autoclave is pemitted up to 250 times Fig 5 12 Vacuum Handpiece and Saliva...

Page 30: ...ntamination is removed or not after cleaning Continue the cleaning if contamination is remained C Immersed with an alkaline disinfection or detergent for 5 minutes We recommend to use ID212 made by DU...

Page 31: ...ig 5 17 The water lter in the junction box needs to be replaced at least once a year The air lter in the junction box needs to be replaced at least once every three years Contact your local service re...

Page 32: ...chieved as a result of re inspection Check of motions of equipment Troubles such as injury in patient s oral cavity and equipment failure may arise Control the water flow in accor dance with Control o...

Page 33: ...h cannot be turned off or if the main valve cannot be closed Product s moving parts No abnormal noise or the like shall be produced from product s moving parts when the product is operated The product...

Page 34: ...tion Standard Lifetime No 3 years 8 9 3 years 10 5 years 5 years 11 12 3 years Regulator Valves Switches Film viewer body part Pressure gauge Arm section of moving part Control PCBs 6 3 years 13 7 yea...

Page 35: ...45 90 135 180 225 270 and 315 0 UT 1cycle and 70 UT 25 30 cycles at 0 single phase 0 UT 250 300 cycles 0 UT 0 5 cycles 0 45 90 135 180 225 270 and 315 0 UT 1cycle and 70 UT 25 30 cycles at 0 single ph...

Page 36: ...ls such as antenna cablesand external antennas should be used no closer than 30 cm 12 inches to any part of the CLESTA including cables specified by the manufacturer Otherwise degradation of the perfo...

Page 37: ...ce hose are designed and manufactured in accordance with ISO9168 2009 DENTISTRY HOSE CONNECTORS FOR AIR DRIVEN DENTAL HANDPIECES However there still could be a case that the connectors of turbines or...

Page 38: ...er to take in cotton and swab for dental treatment Receptacle to do away with used cotton etc intended use etc Model number MCL 04NH 1B Quick connector that provides external equipment with air Model...

Page 39: ...I Product DENTAL UNIT CLASS IIa Model CLESTA CLASS IIa has been de ned by the rule 9 of MDD Annex IX The product has been designed and manufactured in accordance with the European standards as the li...

Page 40: ...42 0083 Japan TEL 81 6 6213 5945 FAX 81 6 6212 3680 TAKARA BELMONT CORPORATION Printed in Japan 2019 12 BOOK NO FEFA27Y0 NOTE TAKARA COMPANY EUROPE GmbH Berner Strasse 18 60437 Frankfurt am Main Germa...

Reviews: