Belmont BELRAY II 097 Operator Instructions Manual Download Page 12

-

10

-

Error

Code

Condition

Step to be Taken

Possible Solution

E.22

E.23

Failure of electrical communication between

the power PCB and timer PCB.

Turn off the main power

switch and wait for

approximately 2 min.

Turn on the main power

switch again.

Contact customer 

service

Any switch on the sub controller is depressed 

when the main power switch is turned on. 

(Except the exposure switch)

Release all the 

switches

Do not turn on the 

power while other 

switch is depressed.

[ 10 ] MAINTENANCE

   

The 

BELRAY II MODEL 097 x-ray unit requires post installation confirmation and periodic 

   maintenance checks to be performed by dealer service personnel. These procedures ensure that the 

   x-ray unit is functioning within the manufacture’s specifications and remains in compliance with

   the Standard.

   It is responsibility of the owner of the unit to see that these maintenance checks are done 

once 

   

a year

 and that they are performed by a trained, certified service technician.

   The specific instructions to perform these checks are located within the BELRAY II MODEL 097

   Installation Manual.

    A. Line voltage confirmation

    B. Tube current confirmation

    C. Inspection of arm and head movement 

    D. Mechanical safety

       1. The wall plate should be checked to confirm that it is securely attached to the wall.

       2. The arm mounting bracket should be checked to confirm that it is securely attached to the 

           wall mounting plate. The arm mounting bracket must be level horizontally and vertically.

       3. Check and verify that the horizontal arm is not raising up and out of the arm mounting bracket.

           This should be verified routinely by treatment room personnel.

 

 

     

>@',6326$/

   

 'LVSRVDORI[UD\XQLWRUFRPSRQHQWV

   

7KH WXEH KHDG RI WKLV [UD\ XQLW FRQWDLQV WKH OHDG IRU [UD\ VKLHOG DQG RLO IRU LQVXODWLRQ

   

:KHQ GLVSRVLQJ WKH [UD\ XQLW RU FRPSRQHQWV  DSSURSULDWO\ GLVSRVH FRPSO\LQJ ZLWK DOO

   

FXUUHQWDSSOLFDEOHUHJXODWLRQVDQGORFDOFRGHV

   

 'LVSRVDORIXVHGILOPDQG&&'FRYHU

   

'LVSRVH WKH XVHG ILOP FRYHUV DQG &&' VHQVRU FRYHUV DSSURSULDWHO\ DFFRUGLQJ WR

   

SUHFHGXUHV LQGLFDWDWHG E\ HDFK PDQXIDFWXUHU DQG DOO FXUUHQW DSSOLFDEHO UHJXUDWLRQV DQG

   

ORFDOFRGHV

Summary of Contents for BELRAY II 097

Page 1: ...R OPERATOR S INSTRUCTIONS for USA Canada WARNING This X ray unit may be dangerous to patient and operator unless safe exposure factors operating instructions and maintenance schedules are observed DEN...

Page 2: ...F CONTROLS 4 4 OPERATING PROCEDURES 7 5 ESTIMATED AIR KERMA 7 6 OPTIONAL HAND EXPOSURE SWITCH 7 7 DIGITAL IMAGING SYSTEM 8 8 DISINFECTION AND CLEANING 8 9 ERROR CODES 9 10 MAINTENANCE 10 11 DISPOSAL 1...

Page 3: ...housing assembly 097 H b X ray controls 097 CM main controller 097 CS sub controller c Cones 097 R regular 097 L long d Balance arm 097 A 4 COMPLIANCE WITH STANDARD The BELMONT BELRAY II MODEL 097 x r...

Page 4: ...re warning light be at least 2 m away from the x ray head and patient and out of the path of the x ray beam or be positioned behind a protective device fully use all radiation protection devices acces...

Page 5: ...justing Switch Down 12 Digital Imaging Switch 4 ExposureTimeAdjusting Switch Up 13 4 mA Selction Switch 5 Tooth Selection Switch T1 6 Tooth Selection Switch T2 7 Tooth Selection Switch T3 8 Tooth Sele...

Page 6: ...I 0DQGLEOH 7 QFLVRU RI 0D LOOD XVSLG 3UHPRODU RI 0DQGLEOH 7 XVSLG 3UHPRODU RI 0D LOOD 0RODUV RI 0DQGLEOH LWHZLQJ 7 0RODU RI 0D LOOD LWHZLQJ 0RODUV 7 2FFOXVDO I WKH 7 VZLWFK LV GHSUHVVHG PRUH WKDQ VHF...

Page 7: ...PRPHQWDULO GLVSOD V WKH VSHHG EHLQJ VHOHFWHG LQ WKH SRVXUH 7LPH LVSOD LQGRZ LWK WKH IDFWRU VSHHG VHWWLQJ G 08 WKH H SRVXUH WLPH EHFRPHV KDOI RI 08 VHWWLQJ As the sensitivity is different according to...

Page 8: ...osure and an error code E 00 will be displayed in Exposure Time Display Window 16 6 switch once after setting to child If the weight of child is over 30kg and less than 50kg press Speed Setting mA Chi...

Page 9: ...6ZLWFK in RUGHU WR SUHYHQW DFFLGHQWDO exposures when the unit is not in XVH 127 I WKH XQLW OHIW RYHU PLQ ZLWKRXW EHLQJ RSHUDWHG DQG WKH 0DLQ 3RZHU 6ZLWFK LV NHSW RQ ILJXUH UXQV WKURXJK WKH SRVXUH 7LPH...

Page 10: ...QLQJ RI WKH SDUWV WKDW PD FRPH LQ FRQWDFW ZLWK VNLQ SHULRGLF GLVLQIHFWLRQ ZLWK D QRQ FRUURVLYH VXUIDFH GLVLQIHFWDQW LV UHFRPPHQGHG 5HFRPPHQGHG GLVLQIHFWDQW XUU HQWDO 237 0 7 6FL DQ WG U LQJ OORZ VXUID...

Page 11: ...Malfunction of the microcomputer Tube current is detected during pre heating period Tube current is detected when main power switch is turned on Exposure switch or exposure circuit had been ON when ma...

Page 12: ...ed service technician The specific instructions to perform these checks are located within the BELRAY II MODEL 097 Installation Manual A Line voltage confirmation B Tube current confirmation C Inspect...

Page 13: ...long cone 1 9 3 3 mGy sec 40 Data obtained by direct measurement in the useful beam 16 Nominal electrical output of H V Generator 0 36kW at 70kVp 7mA 17 Cone Source to skin distance Field size a Regu...

Page 14: ...netic emissions Emissions test Test procedure Compliance Note The emissions characteristics of this equipment make it suitable for use in industrial areas and hospitals CISPR 11 class A If it is used...

Page 15: ...ding cables specified by the manufacturer Otherwise degradation of the performance of this equipment could result Radiated RF IEC61000 4 3 80 MHz 2700 MHz 3V m unmodulated r m s 80 AM 1kHz 80 MHz 2700...

Page 16: ...w Jersey 08873 U S A TEL 732 469 5000 800 223 1192 Fax 732 526 6322 800 280 7504 www belmontequip com TAKARA COMPANY CANADA LTD 2455 Meadowvale Boulevard Mississauga Ontario L5N 5S2 Canada TEL 905 816...

Reviews: