Intended Use of the Product

This product is intended 

exclusively for use in conjunction with procedures that are limited to the examination

 

and treatment of dental patients,

 and must be operated by qualified dentists, or by dental staff that are 

under the supervision of the dentist. Such dentists or dental 

staff

 

should instruct and/or assist patients 

when they are being seated for dental procedures and when exiting from the product. Patients should not 

be allowed to operate or handle the product.

Environmental Requirements

   Operating          Ambient Temperature       

32

°F ~ 104°F  (

0

°C ~ 40°C)

                             Humidity                          

10% ~ 95%

                             Atmospherical Pressure   10psi ~ 15.4psi (700hpa ~ 1060hpa)

   Storage              Ambient Temperature      -4°F ~ 158°F  (-20°C ~ 70°C)

                             Humidity                          10% ~ 95%

                             Atmospherical Pressure    10psi ~ 15.4psi (700hpa ~ 1060hpa)

Classification

  a. Protection against electric shock : Class I Equipment, Type B Applied Parts       (Headrest, 

      Backrest and Seat cushions)

  b. Protection against water ingress : Chair (IPX0), Foot control (IPX1)

  c. Equipment not suitable for use in the presence of a flammable anesthetic mixture with air or with 

      oxygen or nitrous oxide.

  d. Mode of operation : Non-continuous operation 

                                       Maximum activation time: 3 minutes, Duty cycle 1:5

Symbol

Applied part complying with the specified requirements of IEC60601-1:2005 to provide 

protection against electrical shock, particularly regarding allowable patient leakage current 

and patient auxiliary current.

Caution, warning or note 

Manufacturer

Date of Manufacture 

WARNING

California Proposition 65

Cancer and Reproductive Harm - www.P65Warnings.ca.gov.

Summary of Contents for B50N

Page 1: ...manual provides operating instructions for the B50N Chair The instructions contained in this booklet should be throughly read and understood before operating the chair After the installation has been...

Page 2: ...rical Pressure 10psi 15 4psi 700hpa 1060hpa Storage Ambient Temperature 4 F 158 F 20 C 70 C Humidity 10 95 Atmospherical Pressure 10psi 15 4psi 700hpa 1060hpa Classi cation a Protection against electr...

Page 3: ...nt has been positioned Take extreme care with patients that have a pacemaker Prior to operation of the chair ask patient to verify whether they have a pacemaker When operating chair be certain patient...

Page 4: ...oot Control Ass y 17 Sub Link Cover Lower 18 Main Power Switch 19 Fuse Holder 20 Backrest Control Panels 21 Side Frame Left 22 Side Frame Right Figure 1 Figure 2 BACKREST CONTROL Figure 3 FOOT CONTROL...

Page 5: ...5 2 20mm Hospital grade plug Base component housing formed from solid color acrylate styrene acrylonitrile ASA V0 All exposed ferrous parts covered with corrosion resistant paint or plating Weight 32...

Page 6: ...of forward facing armrests or on their lap All patients are at risk of potential injury if these precautions are not followed Do not allow patient to sit on the headrest armrest backrest or on the fr...

Page 7: ...Pre set 3 is operated by LP button Auto Return Momentarily depress A button on the backrest control or 0 button on the foot control the chair will return to the initial position The seat is fully low...

Page 8: ...n so it is even with the occipital of the patient s head Viewing the lower arch 1 Using the latch release button white pivot the headrest cushion half way toward the patient s head 2 Have the patient...

Page 9: ...Bleach Phenol Alcohol combinations Foam spray products Benzalkonium chloride solutions Use with Caution Water based phenolic disinfectants following manufacturer s exact instructions for use Warranty...

Page 10: ...seat motion activation resulting in potential injury and or damage to equipment If the main power cannot be turned off discontinue use of product immediately and contact an authorized Belmont dealer f...

Page 11: ...i t p i r c s e D s t r a P o N s r a e y 2 m s i n a h c e M t s e r d a e H 1 2 Electric wiring of moving parts 2 years 3 Switches for operating equipment 2 years Transformer 3 years 4 3 Base Cover...

Page 12: ...sion of Takara Belmont USA Inc 101 Belmont Drive Somerset New Jersey 08873 U S A TEL 732 469 5000 800 223 1192 FAX 732 356 1035 Importer for Canada TAKARA COMPANY CANADA LTD 2455 Meadowvale Blvd Missi...

Reviews: