7.2 - Troubleshooting
Problems that may arise when using the log splitter and recommended remedies are given in the table below. In the case of operations carried out by
unauthorised personnel, the guarantee will be immediately null and void and the manufacturer will be relieved of any responsibility for injury to persons
and animals and damage.
SCRAPPING AND DISPOSAL OF THE MACHINE
The machine must be scrapped in compliance with all safety regulations for the prevention of personal injury and damage to the environment and animals.
All parts of the machine must be scrapped and disposed of in accordance with applicable legislation in the place of scrapping.
Dispose of hydraulic
fl
uid and electric parts correctly. Do not dispose of these in the environment, as they are hazardous pollutants, and treat them
in accordance with applicable legislation.
Machines
fi
tted with electrical parts must not be disposed of as general waste and must be separated for disposal as separately collected fractions,
deposited at authorised collection points.
The manufacturer is committed to waste recycling (WEEE) and is a member of specialised waste disposal consortiums.
Incorrect waste disposal is punishable by law.
Problem
Log fails to split
Rod advances jerkily or with strong vibra-
tions. Foamy oil comes out from the
fi
ller
cap.
Oil leak from the unions, pump or cylinder
Corrective action
Try to cut a small part or use other means to
reduce the size of the log
Change the position of the log in relation to
the wedge
Sharped the wedge, check for burrs or nicks,
fi
le if necessary
Locate the leack using a piece of card or wood.
Contact your dealer
Contact your dealer
Check oil level. Top up if necessary.
Check that the pump does not suck up any air.
Check that the connections are not restricted
or the pipes damaged in the system from the
tank to the pump.
If problem remain contact your dealer
Tighten unions
Contact your dealer
Probable cause
Log exceeds permitted dimensions
Incorrect positioning of the log
Wedge do not cut
Oil leack
Hydraulicpressure too low
Air in the circuit
Unions not properly tight
Seals worn
ENGLISH
7.3 - Resetting of the thermal cut-out of the electric motor
In the case of machines with electric motor, a protection device applied to the motor and integrated in the main on/off switch is tripped in the case of
overloads, sudden increases in voltage or accidental faults in the electrical system. In this case, before calling your authorised service centre, wait a
few minutes and then try to reset the main on/off switch. If the problem does not re-occur, the log splitter can be used normally. If the cut-out is tripped
again, do not try to reset it and contact your ahthorised service centre.
Summary of Contents for STS T10 E
Page 2: ...2 D22002300 v 0 UPD 180612 s r l 1 4 5a 5b 3 2...
Page 3: ...3 D22002300 v 0 UPD 180612 s r l 6a 6b 6c 6d 7a 7b 7c 7d...
Page 4: ...4 D22002300 v 0 UPD 180612 s r l 8a 8b 8d 8e 8c 9a 9b...
Page 5: ...5 D22002300 v 0 UPD 180612 s r l 10 A B C D 12a 12b 11...
Page 54: ...54 D22002300 v 0 UPD 180612 s r l...
Page 55: ...55 D22002300 v 0 UPD 180612 s r l...