Making an Emergency Call (Alarm)
An alarm call may be initiated at each M200+ room unit by one of the following
methods:-
a)
Operation of the
Call Button
(Orange button at the bottom of the unit).
b)
Operation of the
Pull-Cord
at the bottom of the M200+ unit (if fitted).
d)
Operation of the
Remote Switch
e.g. Illuminated ceiling pull switch.
e)
Activation of the
Smoke Detector
.
c)
Operation of the
'Pear-drop switch'
or other device which is plugged into the
jack-socket (or by inadvertent removal of the jack plug)
In each case the M200+ room unit will illuminate the
Re-Assurance Lamp (Red LED)
and
illuminated ceiling pull-switches
(if present).
The staff are alerted to alarms by:-
a)
Any room unit enabled as a Master/Monitor sounding an alarm tone, (provided
the unit is programmed to do so).
b)
Extension alarms, such as an audible alarm or flashing lamp (if present).
c)
A radio pager (if available).
A variety of alarm tone sounds may be programmed for each alarm type, e.g. the fire
alarm could be set to a continuous tone and the pull cord set to an intermittent warble.
Refer to the Installation Manual for full details of how to set the alarm tones.