Plexus 9000 Planning and Engineering Guide
Planning for Provisioning
Section 130-200-100
Issue 11, January 24, 2003
Telica, Inc.
6-43
Table 6.2-F. IOM Provisioning
Parameter Description
oc_id - IOM-8, IOM-8-OC3/12-{1-4}, IOM-8-STM1/4-{1-4}
ds3_id - IOM-{1-17} or IOM-{1-17}-T3-{1-8}
sts_id - IOM-{1-17} or IOM-{1-17}-STS-{1-8}
ds1/e1_id - IOM-{1-17} or IOM-{1-17}-PORT-{1-28}
xx_id
enet_id - IOM-{8}-ENET-{1-4}
OC/STM - Line code - NRZ or RZ
DS3 – Line format - ASYNC or CBIT
DS1 - Line format - SF or ESF
linecde
E1 - CRC, CRC MF, DB or, MF
DS3 - Line code - B3ZS or CCHAN
linecde
DS1 – Line code - AMI or B8ZS
stsmap (sts)
STS-1 - VTLOCK or VTFLOAT
lbo or eqlz
Line build out (cable length to cross-connect)
omode
OOS signal sent - AIS or
NORM
mode (enet)
autoneg, halfduplex, fullduplex
format (enet)
ENET_802_3 or ENET_DIX_II
pst
Primary State - IS or OOS
Table 6.2-G. Point Codes and Signaling Provisioning
Parameter Description
Originating Point Code (ownPc)
Destination Point Code (rem)
pc
Adjacent switches (adj)
pcPrflId
Point code profile ID – (1-128)
mtp3PrflId
Layer 2 profile ID - (1-40)
mtp3PrflId
Layer 3 profile ID - (1-20)
lsetId
Link set ID - (1-20)
IOM-{1-17} or IOM-{1-17}-T3-{1-8}
IOM-{1-17} or IOM-{1-17}-STS-{1-8}
port
IOM-{1-17} or IOM-{1-17}-PORT-{1-28}
lnkSpeed
Link speed of signaling link (56K or 64K)
routeSs7
Adjacent DPC and connecting link set