background image

Encontre Belimo na RSA - A mais completa em soluções para HVAC e Automação - 

Avenida Ragueb Chohfi, 960 - Torre 3, Sala 73 - Jardim Três Marias, São Paulo-SP, Cep: 08375-000 

Telefone Sac: 55 11 2031 6658 / Whats App 55 11 9799 6574 - Email: 

[email protected]

 - Site: http://www.rsistemas-automacao.com.br/empres/empres.aspx

 

 

  

  3.46"   

 

[88] 

8.5" [216] 

3.3" 
[84] 

2.49" 
[63.4] 

1.35" 

[35] 

  

    A     

 

 

AR...24-3 Actuators, On/Off, Floating Point 

 

 
 
 
 
 
 
 
 
 
 
 
 

 

Models 

ARB24-3 
ARB24-3-S 

w/built-in Aux. Switch 

ARX24-3 

Flexible 

ARX24-3-S 

Flexible w/built-in Aux. Switch 

ARB24-3-5-14 
ARX24-3-5-14 

 

 Dimensions with 2-Way  Valve 

 

 

 

Valve Nominal Size 

Dimensions (Inches [mm]) 

Valve Body 

Inches  DN [mm] 

 

B231-B232 

1¼” 

32 

3.72” [94.6] 

1.98” [50.4] 

B238-B240 

1½” 

40 

3.88” [98.5] 

1.98” [50.4] 

B248-B250 

2” 

50 

4.21” [107.0] 

2.21” [56.2] 

B251-B254 

2” 

50 

4.93” [125.2] 

2.68” [68.0] 

B261-B265 

2½” 

65 

5.55” [140.9] 

2.68” [68.0] 

B277-B280 

3

” 

80 

5.82” [147.9] 

2.68” [68.0] 

 

 Technical  Data 

 

Control 

on/off, floating point 

Power supply 

24 VAC ± 20% 50/60 Hz 
24 VDC ± 10% 

Power consumption 

running 

holding 

2.5 W 
0.2 W 

Transformer sizing 

5.5 VA (class 2 power source) 

Electrical connection 

 

ARB24-3... 
ARX24-3... 

½” conduit connector 
18 GA plenum rated cable 
3 ft. [1m] 
3 ft. [1m] 10 ft. [3m] 16 ft. [5m] 

Overload protection 

electronic throughout 0° to 95° rotation 

Input impedance 

600 



Angle of rotation 

90°, adjustable with mechanical stop 

Direction of rotation 

reversible with protected 

 

Position indication 

handle 

Manual override 

external push button 

Running time 

ARB24-3... 
ARX24-3... 

 

90 seconds 
300, 150, 90 seconds, 
constant independent of load 

Humidity 

5 to 95% RH non-condensing (EN 60730-1) 

Ambient temperature 

-22°F to 122°F [-30°C to 50°C] 

Storage temperature 

-40°F to 176°F [-40°C to 80°C] 

Housing 

NEMA 2/IP54 

Housing material 

UL94-5VA 

Agency listings† 

cULus according to UL 60730-1A/-2-14, 
CAN/CSA E60730-1:02, CE according to 
2004/108/EC and 2006/95/EC for line voltage 
and/or 

–S versions 

Noise leve 

<45 dB(A) 

Quality standard 

ISO 9001 

 

AR...24-3-S 

Auxiliary switch (-S models)  1 x SPDT, 3A (0.5A) @ 250 VAC, UL Listed, 

adjustable 0 to 90° 

† Rated impulse voltage 800V, Control pollution degree 3, Type of action 

(1.B for -S models) 

 Dimensions with 3-Way  Valve 

 

 

 

Valve Nominal Size 

Dimensions (Inches [mm]) 

Valve Body   nches DN [mm] 

B329-B331 

1¼” 

32 

3.96” [100.6]  2.21” [56.2]  2.14” [54.3] 

B338-B341 

1½” 

40 

4.39” [111.6]  2.45” [62.2]  2.33” [59.1] 

B347-B352 

2” 

50 

4.90” [124.5]  2.68” [68.0]  2.60” [66.0] 

 

 

D

1

5

2

 

D

1

5

5

 

O

5

0

9

0

5

 - 

0

5

/1

2

 - 

S

u

b

je

c

t to

 c

h

a

n

g

e

. ©

 B

e

lim

o

 A

ir

c

o

n

tr

o

ls

 (U

S

A

),

 In

c

Summary of Contents for ARB24-3

Page 1: ...3 conduit connector 18 GA plenum rated cable 3 ft 1m 3 ft 1m 10 ft 3m 16 ft 5m Overload protection electronic throughout 0 to 95 rotation Input impedance 600 Angle of rotation 90 adjustable with mecha...

Page 2: ...oduct it may be necessaryto work with live electrical components Have a qualified licensed electrician or otherindividual who has been properly trained in handling live electrical components perform t...

Page 3: ...cted Position indication handle Manual override external push button Running time ARB24 SR ARX24 SR 90 seconds 300 150 90 seconds constant independent of load Humidity 5 to 95 RH non condensing EN 607...

Page 4: ...Electrical Components During installation testing servicing and troubleshooting of this product it may be necessaryto workwith live electrical components Have a qualifiedlicensed electrician or other...

Page 5: ...g time ARB120 3 ARX120 3 90 seconds 300 150 90 seconds constant independent of load Humidity 5 to 95 RH non condensing EN 60730 1 Ambient temperature 22 F to 122 F 30 C to 50 C Storage temperature 40...

Page 6: ...n WARNING LIVE Electrical Components Duringinstallation testing servicingandtroubleshootingofthisproduct itmay be necessaryto workwith live electrical components Have a qualifiedlicensed electrician o...

Page 7: ...on indication handle Manual override external push button Running time ARB120 SR ARX120 SR 90 seconds 300 150 90 seconds constant independent of load Humidity 5 to 95 RH non condensing EN 60730 1 Ambi...

Page 8: ...nd 230 VAC actuators use appliance rated cables Meets cULus or UL and CSA requirements without the need of an electrical ground connection WARNING LIVE Electrical Components Duringinstallation testing...

Page 9: ...Position indication handle Manual override external push button Running time ARB24 MFT ARX24 MFT 150 seconds variable 90 to 350 seconds Humidity 5 to 95 RH non condensing EN 60730 1 Ambient temperatu...

Page 10: ...ller The actuator internal common reference is not compatible Controlsignalmaybepulsed fromeitherthe Hot source or the Common sink 24 VAC line Contact closures A B also can be triacs A B should both b...

Page 11: ...ride external push button Running time 150 seconds default Humidity 5 to 95 RH non condensing EN 60730 1 Ambient temperature 22 F to 122 F 30 C to 50 C Storage temperature 40 F to 176 F 40 C to 80 C H...

Page 12: ...may also be powered by 24 VDC WARNING LIVE Electrical Components During installation testing servicing and troubleshooting of this product it may be necessaryto workwith live electrical components Ha...

Page 13: ...verride external push button Running time 150 seconds default variable 90 to 350 seconds Humidity 5 to 95 RH non condensing EN 60730 1 Ambient temperature 22 F to 122 F 30 C to 50 C Storage temperatur...

Page 14: ...Open Damper Closed Dimensions with 2 Way Flanged Valve 1 3 4 O50905 05 12 Subject to change Belimo Aircontrols USA Inc D151_A The direction of rotation switch is set so that the fail safe position and...

Reviews: