![Belden Miranda Kaleido-X16 Release Notes Download Page 33](http://html1.mh-extra.com/html/belden/miranda-kaleido-x16/miranda-kaleido-x16_release-notes_2725597033.webp)
29
Kaleido-X
Release Notes
•
[Ref. #34987]
Alarm scheduling:
If non-recurring schedules were in progress before a
multi-viewer restarted, the associated actions (alarm inversion or suppression) may fail
to be applied once the system has restarted.
Workaround:
For every schedule you need to resume, open the
Schedule Entry Details
window and then click
OK
: (1) On the
Tools
menu, click
Edit schedules
. (2) In
Edit
Schedule
, select a schedule you wish to resume (to locate them, notice that they have
nothing indicated under
Recurrence
, and are reported as
In progress
under
Status)
, click
Edit
to open
Schedule Entry Details,
and then click
OK
to close the window.
•
[Ref. #35575]
Background actions:
A background action triggered by an alarm is
executed, regardless of the alarm’s operational mode.
•
[Ref. #35463]
Kaleido-IP alarms:
In the case of the Kaleido-IP, video alarms are only
supported for signals whose video resolution’s horizontal dimension is a multiple of 16.
•
[Ref. #21940/32585]
Background actions:
Background actions created from the main
System list in the
Description/Calibrations
tab, or from the filtered System list
associated with the current level in the sources table, cannot be saved from these tabs.
Workaround:
To save background actions created from the
Description/Calibrations
tab, or from the
Channels/Sources
tab, switch to the
Actions
tab, and then click
Save
on
the toolbar.
•
[Ref. #27563]
Kaleido-IP alarm debouncing:
In the case of a Kaleido-IP multi-viewer, the
current version of the Kaleido-X software does not support alarm-debouncing
calibrations. The default debouncing parameters of three occurrences of a five-second
error state over a detection window of one minute apply to most alarms.
•
[Ref. #25338]
KMV-3901/3911 card LED configuration:
With the current version of the
KMV-3901/3911 multi-viewer, changes made to alarm contributions affecting the card
LED behavior revert to default settings when the multi-viewer restarts.
•
[Ref. #23882]
GSM Alarm Browser:
Kaleido-X systems that have legacy KXO-Dual cards
with only 1 GB RAM are subject to the following limitation. An alarm that is not
published (i.e., most alarms) is only visible in the iControl Alarm Browser if the alarm is
already monitored on the monitor wall, or by a background action, or otherwise (e.g., in
iControl or XEdit).
Workaround:
To force an alarm to appear in the iControl Alarm Browser, connect to the
Kaleido-X multi-viewer by using XEdit, and then navigate to the desired alarm in the
System hierarchical list.
Note:
The alarm configuration interface for the KMV-3901/3911 multi-
viewer is available from the KMV-3901/3911 control panel included with
iControl version 3.60 and later.
IMPORTANT
To fully benefit from all new features introduced in Kaleido-X version 5.00,
every legacy KXO-Dual card that does not have a 2-GB memory module must
be upgraded to 2 GB (see
Kaleido-X systems may require a RAM upgrade
page 1).