CPU-ETH2 Controller Card
Options
Get alarm keys
Click this button to open a save dialog
where you can save a file containing a
list of all alarms on this controller and
their current values, along with an
Alarm Key for each. The alarm keys are
useful for system integration and
troubleshooting.
The file is saved in .csv format
OK, Apply, Cancel
OK
accepts the settings and closes the window once the controller confirms that there are
no errors.
Apply
accepts the settings, but leaves the window open
Cancel
closes the window without applying any changes, and leaves the previous settings
intact.
Using the Menu
Access the Alarm Report menu item, and scroll through the list of available alarms, setting
each to OFF or to report through GPI. Use the GPI Report item to turn GPI reporting on or
off.
Options
The Ethernet Link Redundancy option uses channel bonding between the two rear panel
ethernet interfaces to achieve redundancy (Active Backup mode) or increased throughput
(Round Robin mode).
Round-Robin: This mode provides load balancing, fault tolerance and increased
throughput. Transmissions are received and sent out sequentially on each bonded slave
interface beginning with the first one available. This mode requires that the remote
equipment (host or switch) be configured to aggregate traffic over several ports (Trunk,
EtherChannel, etc).