background image

Installation  SPIDER-SL  PoE

 

8

 

 

  Release 01    05/2019

 

About this Manual 

 
The “Installation User Manual” document contains a device description, 
safety instructions, a display description and further information that you 
require to install the device. 

 

Legend 

 

The symbols used in this manual have the following meanings: 

 

  Listing 

 

 

Work step 

 

 

Subheading 

 

 
 

 

Summary of Contents for Hirschmann SPIDER Standard Line Series

Page 1: ...Installation SPIDER SL PoE Technical support Release 01 05 2019 https hirschmann support belden com User Manual Installation Industrial Ethernet Rail Switch SPIDER Standard Line PoE ...

Page 2: ...rmance features described here are binding only if they have been expressly agreed when the contract was made This document was produced by Hirschmann Automation and Control GmbH according to the best of the company s knowledge Hirschmann reserves the right to change the contents of this document without prior notice Hirschmann can give no guarantee in respect of the correctness or accuracy of the...

Page 3: ...14 1 6 Pin assignments 15 1 7 Display elements 16 1 7 1 Power supply state 16 1 7 2 Port state 17 1 7 3 PoE state 17 2 Installation 18 2 1 Checking the package contents 18 2 2 Mounting the device 19 2 2 1 Installing the device onto the DIN rail 19 2 2 2 Grounding the device 19 2 3 Installing an SFP transceiver optional 20 2 4 Adjust DIP switch settings 21 2 5 Wiring the terminal block for the supp...

Page 4: ...he product only according to the technical specifications See Technical data on page 27 Connect to the product only components suitable for the requirements of the specific application case Installation site requirements Install the device in a fire enclosure according to EN 60950 1 Device casing Only technicians authorized by the manufacturer are permitted to open the casing Never insert pointed ...

Page 5: ... free The cables used are permitted for the temperature range of the application case This device must be operated with a separate power supply or DC DC converter with galvanically separated SELV PELV output voltages Requirements for connecting the supply voltage The following requirements apply alternatively Alternative 1 The power supply complies with the requirements for a limited power source ...

Page 6: ...with the above named EU directive s the EU conformity declaration will be available to the relevant authorities at the following address Hirschmann Automation and Control GmbH Stuttgarter Str 45 51 72654 Neckartenzlingen Germany The device can be used in the industrial sector Interference immunity EN 61000 6 2 Emitted interference EN 55032 You find more information on technical standards here Tech...

Page 7: ...hese requirements are designed to provide sufficient protection against interference when the device is being used in a business environment The device creates and uses high frequencies and can also radiate these frequencies If it is not installed and used in accordance with this operating manual it can cause radio transmission interference The use of this device in a residential area can also cau...

Page 8: ...The Installation User Manual document contains a device description safety instructions a display description and further information that you require to install the device Legend The symbols used in this manual have the following meanings Listing Work step Subheading ...

Page 9: ...ice characteristics You can determine the possible combinations using the configurator which is available in the Belden E Catalog www e catalog beldensolutions com on the web page of the device 1 2 Device name and product code The device name corresponds to the product code The product code is made up of characteristics with defined positions The characteristic values stand for specific product pr...

Page 10: ...0 21 Optical fiber port 2 O6 SFP slot for 100 1000 Mbit s F O connections 99 without 22 23 Optical fiber port 3 99 without 24 Temperature range T Extended 40 C 70 C 40 F 158 F 25 26 Certificates and declarations Z9 CE FCC EN61131 27 28 Customer specific version HH Hirschmann standard 29 30 Configuration HH Hirschmann standard Table 1 Device name and product code ...

Page 11: ...PIDER SL 44 05T199 1 LED display elements for power supply status 2 4 pin pluggable terminal block for power supply 3 DIP 4 LED display elements for port status 5 1 RJ45 socket for 10 100 1000 Mbit s Twisted Pair connections 6 9 4 RJ45 socket for 10 100 1000 Mbit s PoE port 10 LED display elements for PoE status SPIDER SL 44 08T19999 1 LED display elements for power supply status 2 4 pin pluggable...

Page 12: ...bit s F O connections DSC singlemode socket for 100 Mbit s F O connections ST multimode socket for 100 Mbit s F O connections ST singlemode socket for 100 Mbit s F O connections 6 9 4 RJ45 socket for 10 100 Mbit s PoE port 10 LED display elements for PoE status SPIDER SL 24 05T1 1 LED display elements for power supply status 2 4 pin pluggable terminal block for power supply 3 DIP 4 LED display ele...

Page 13: ...ables via the wire pairs carrying the signal Alternative A You find information on pin assignments for making patch cables here Pin assignments on page 15 1 5 1 10 100 1000 Mbit s twisted pair port This port is an RJ45 socket The 10 100 1000 Mbit s twisted pair port offers you the ability to connect network components This port supports Autonegotiation Autopolarity Autocrossing 1000 Mbit s full du...

Page 14: ...t s PoE port This port is an RJ45 socket The 10 100 Mbit s PoE port allows you to connect network components such as a powered device PD This port supports Autonegotiation Autopolarity Autocrossing 100 Mbit s half duplex mode 100 Mbit s full duplex mode 10 Mbit s half duplex mode 10 Mbit s full duplex mode Power over Ethernet PoE PoE 1 5 5 100 1000 Mbit s F O port This port is an SFP slot The 100 ...

Page 15: ...lex mode 1 6 Pin assignments Pin assignment of a TP TX interface in MDI mode RJ45 socket RJ45 Pin 10 100 Mbit s 1000 Mbit s PoE voltage MDI mode 1 TX BI_DA Plus terminal 2 TX BI_DA Plus terminal 3 RX BI_DB Minus terminal 4 BI_DC 5 BI_DC 6 RX BI_DB Minus terminal 7 BI_DD 8 BI_DD ...

Page 16: ...lf test During this process various LEDs light up 1 7 1 Power supply state This LED provides information on the status of the power supply LED Color Activity Meaning P1 Green Lights up The operating voltage 1 is on None The operating voltage 1 is off P2 Green Lights up The operating voltage 2 is on None The operating voltage 2 is off ...

Page 17: ...tivity Meaning Green Lights up Device detects a valid link Flashing Device is transmitting and or receiving data None Device detects an invalid or missing link 1 7 3 PoE state These LEDs provide information on the status of the PoE LED Color Activity Meaning Green Lights up The PoE power supply is active None The PoE power supply is inactive ...

Page 18: ...gure a subdomain follow these steps Checking the package contents Mounting the device Installing an SFP transceiver optional Wiring the terminal block for the supply voltage and the grounding Operating the device Connecting data cables 2 1 Checking the package contents Check whether the package includes all items named in the section Scope of delivery on page 30 Check the individual parts for tran...

Page 19: ...nting on a 35 mm DIN rail in accordance with DIN EN 60715 Proceed as follows Slide the upper stiff metal spring of the device into the DIN rail Press the device downwards onto the clip in bar Snap in the device 2 2 2 Grounding the device The device has a functional ground connection The device is grounded via the separate ground screw Note Ground the device before connecting any other cables ...

Page 20: ...ver optional Prerequisite Use only Hirschmann SFP transceivers which are suitable for usage with the device See Accessories on page 31 Proceed as follows Remove the protection cap from the SFP transceiver Push the transceiver with the lock closed into the slot until it latches in ...

Page 21: ...me function OFF Disable Jumbo frame function SPIDER SL 44 08T19999 N C Serves no function Jumbo ON Enable Jumbo frame function OFF Disable Jumbo frame function SPIDER SL 44 08T1O6O6 N C Serves no function Jumbo ON Enable Jumbo frame function OFF Disable Jumbo frame function SPIDER SL 24 N C Serves no function Jumbo ON Enable Jumbo frame function OFF Disable Jumbo frame function Note For the SPIDER...

Page 22: ...ck is used for connecting the supply voltage and it is a redundant power A grounded screw is used for the grounding Figure 1 4 pin pluggable terminal block for power supply Type of the voltages that can be connected Specification of the supply voltage Connections DC voltage Rated voltage range DC 12 V 57V Plus terminal of the supply voltage Minus terminal of the supply voltage Table 2 Type and spe...

Page 23: ...cal interference levels Keep the length of the data cables as short as possible Use optical data cables for the data transmission between the buildings When using copper cables provide a sufficient separation between the power supply cables and the data cables Ideally install the cables in separate cable channels Verify that power supply cables and data cables do not run parallel over longer dista...

Page 24: ...cal data on page 27 The ambient air temperature is the temperature of the air at a distance of 2 in 5 cm from the device It depends on the installation conditions of the device e g the distance from other devices or other objects and the output of neighboring devices NOTE We recommend the installation environment for the equipment is 0 8 in 2 cm left and right spacing 2 in 5 cm up and down ...

Page 25: ... according to the specifications Depending on the degree of pollution in the operating environment check at regular intervals that the ventilation slots in the device are not obstructed CAUTION RISK OF TRANSIENTS OR ELECTROSTATIC DISCHARGES Do not open the housing Failure to follow these instructions can result in injury or equipment damage Note You will find information about the complaints and r...

Page 26: ...Pull the SFP transceiver out of the slot by means of the opened lock Close the SFP transceiver with the protective cap 5 2 Removing the device Proceed as follows Disconnect the data cables Disable the supply voltage Remove the power connector from the device Press the device downwards Pull it device from under the DIN rail ...

Page 27: ...eak inrush current 2 77A2 s Climatic conditions during operation Ambient air temperature2 40 C 70 C 40 F 158 F Derating3 Humidity 10 95 non condensing Air pressure minimum 795 hPa 6562 ft 2000 m Climatic conditions during storage Ambient air temperature2 40 º C 85 º C 40 º F 185 º F Humidity 10 95 non condensing Air pressure minimum 795 hPa 6562 ft 2000 m Pollution degree 2 Protection classes Degr...

Page 28: ...Installation SPIDER SL PoE 28 Release 01 05 2019 Dimension drawings Figure 2 Dimensions of device variants SPIDER SL 24 Figure 3 Dimensions of device variants SPIDER SL 44 ...

Page 29: ... MHz 6000 MHz 10 V m Fast transients burst EN 61000 4 4 IEEE C37 90 1 DC supply connection 2 kV EN 61000 4 4 IEEE C37 90 1 Data line 2 kV Voltage surges DC supply connection EN 61000 4 5 line earth 2 kV EN 61000 4 5 line line 1 kV Voltage surges data line EN 61000 4 5 line earth 1 kV Conducted disturbances EN 61000 4 6 150 kHz 80 MHz 10 V Stability IEC 60068 2 6 test Fc Vibration 5 Hz 8 4 Hz with ...

Page 30: ...1 134 5W 457 3 BTU IT h SPIDER SL 24 04T1 134 2W 456 3 BTU IT h Scope of delivery Number Article 1 Device 1 4 pin pluggable terminal block for power supply 1 General safety instructions Order number Device SPIDER SL 44 05T1O69999TZ9HHHH 942 274 001 SPIDER SL 44 05T1999999TZ9HHHH 942 274 002 SPIDER SL 44 08T1999999TZ9HHHH 942 274 003 SPIDER SL 44 08T1O6O699TZ9HHHH 942 274 004 SPIDER SL 24 04T1M2999...

Page 31: ...01 SFP FAST MM LC EECa 942 194 002 SFP FAST SM LCa 942 195 001 SFP FAST SM LC EECa 942 195 002 Bidirectional Gigabit Ethernet SFP transceiver Order number M SFP BIDI Type A LX LC EEC 943 974 001 M SFP BIDI Type B LX LC EEC 943 974 002 M SFP BIDI Type A LH LC EEC 943 975 001 M SFP BIDI Type B LH LC EEC 943 975 002 M SFP BIDI Bundle LX LC EEC type A B 943 974 101 M SFP BIDI Bundle LH LC EEC type A B...

Page 32: ...ity EMC Part 6 2 Generic standards Immunity for industrial environments EN 61131 2 Programmable controllers Part 2 Equipment requirements and tests FCC 47 CFR Part 15 Code of Federal Regulations Table 3 List of the technical standards The device has an approval based on a specific standard only if the approval indicator appears on the device casing The device generally fulfills the technical stand...

Page 33: ...schmann Competence Center The Hirschmann Competence Center is ahead of its competitors Consulting incorporates comprehensive technical advice from system evaluation through network planning to project planning Training offers you an introduction to the basics product briefing and user training with certification The current technology and product training courses can be found at http www hicomcent...

Page 34: ......

Reviews: