Installation RS20/22/30/32/40
Release 07 10/2021
47
2.1
Checking the package contents
Perform the following work steps:
Check whether the package includes all items named in the section
“Scope of delivery” on page 76
Check the individual parts for transport damage.
2.2
Installing and grounding the device
Only when using the PoE power supply unit RPS90/48V HV:
2.2.1
Installing the device onto the DIN rail
Verify that the device maintains the minimum clearance to meet the climatic
conditions during operation:
Top and bottom device side: 10 cm (3.94 in)
Left and right device side: 2 cm (0.79 in)
WARNING
FIRE HAZARD
Install the device in a fire enclosure according to IEC 60950-1.
Failure to follow this instruction can result in death, serious injury, or
equipment damage.
WARNING
ELECTRIC SHOCK
Install this device only in a switch cabinet or in an operating site with
restricted access, to which maintenance staff have exclusive access.
Failure to follow this instruction can result in death, serious injury, or
equipment damage.