Configuration
4.14 Services
Activating the
Enable I/O extension
function allows you monitor the binary I/O inputs on the
router.
Selecting
Enable M-BUS extension
and entering the
Baudrate
,
Parity
and
Stop Bits
lets you
monitor the meter status connected via MBUS interface. MBUS expansion port is not currently
supported, but it is possible to use an external RS232/MBUS converter.
Selecting Enable reporting to supervisory system and entering the
IP Address
and
Period
lets you send statistical information to the monitoring system, R-SeeNet.
Item
Description
IP Address
IPv4 or IPv6 address.
Period
Period of sending statistical information (in minutes).
Table 48: SNMP Configuration (R-SeeNet)
Each monitored value is uniquely identified using a numerical identifier
OID – Object Iden-
tifier
. This identifier consists of a progression of numbers separated by a point. The shape
of each OID is determined by the identifier value of the parent element and then this value is
complemented by a point and current number. So it is obvious that there is a tree structure.
The following figure displays the basic tree structure that is used for creating the OIDs.
Figure 49: OID Basic Structure
The SNMP values that are specific for Hirschmann routers create the tree starting at
OID = .1.3.6.1.4.1.248. You interpret the OID in the following manner:
iso.org.dod.internet.private.enterprises.hirschmann
This means that the router provides for example, information about the internal temperature
(OID 1.3.6.1.4.1.248.40.1.3.3) or about the power voltage (OID 1.3.6.1.4.1.248.40.1.3.4). For
binary inputs and output, the following range of OID is used:
94
UM Configuration OWL LTE M12
Rel. 06.1.09 - 07/2019