background image

Installation OCTOPUS OS20/OS24 Managed

Release 10 08/2017

Technical Support

https://hirschmann-support.belden.eu.com

User Manual

Installation
Managed IP65/67 Switch
OCTOPUS OS20 / OS24

OS20–000900T5T5TAFBHH

OS20–000900T5T5TNEBHH

OS24–080900T5T5TNEBHH

OS24–080900T5T5TFFBHH

4

8

5

9

1

3

2

7

6

P1 P2 RM FAULT

OS20-000900T5T5TAFBHH

x  y

OCTOPUS

OS20

Managed

ETHERNET Switch

Power

OS20-000900T5T5TNEBHH

V24

Function

Pin

1
2
3
4

TX
RX
N.C.
GND

3

4

1

2

V24

Power

N.C.
P

-

1
2
3
4 N.C.

Pin Function

P+

Power

1

2

4

3

FAULT

4

5

1

3

2

8

9

7

6

RM

P

x  y

OCTOPUS

OS20

Managed

ETHERNET Switch

V24

Function

Pin

1
2
3
4

TX
RX
N.C.
GND

3

4

1

2

V24

Fault

Power

N.C.

1

2

3

4

5

N.C.

N.C.

Fault

Fault

P1

FAULT

4

5

1

3

2

8

9

7

6

RM

P2

PoE

PoE

x  y

OCTOPUS

OS24

Managed

ETHERNET Switch

OS24-080900T5T5TNEBHH

V24

Function

Pin

1
2
3
4

TX
RX
N.C.
GND

3

4

1

2

V24

P

Port 2

-

9

Power

N.C.
P

-

1
2
3
4 N.C.

Pin Function

P+

Power

1

2

4

3

FAULT

4

5

1

3

2

8

9

7

6

RM

PoE

PoE

P

x  y

OCTOPUS

OS24

Managed

ETHERNET Switch

OS24-080900T5T5TNEBHH

V24

Function

Pin

1
2
3
4

TX
RX
N.C.
GND

3

4

1

2

V24

N.C.

1

2

3

4

5

N.C.

N.C.

Fault

Fault

Fault

P

Port 2

-

9

OS20-000900T5T5TNEBHH

Summary of Contents for HIRSCHMANN OCTOPUS OS20 Series

Page 1: ...C P 1 2 3 4 N C Pin Function P Power 1 2 4 3 FAULT 4 5 1 3 2 8 9 7 6 RM P x y OCTOPUS OS20 Managed ETHERNET Switch V24 Function Pin 1 2 3 4 TX RX N C GND 3 4 1 2 V24 Fault Power N C 1 2 3 4 5 N C N C Fault Fault P1 FAULT 4 5 1 3 2 8 9 7 6 RM P2 PoE PoE x y OCTOPUS OS24 Managed ETHERNET Switch OS24 080900T5T5TNEBHH V24 Function Pin 1 2 3 4 TX RX N C GND 3 4 1 2 V24 P Port 2 9 Power N C P 1 2 3 4 N ...

Page 2: ...binding only if they have been expressly agreed when the contract was made This document was produced by Hirschmann Automation and Control GmbH according to the best of the company s knowledge Hirschmann reserves the right to change the contents of this document without prior notice Hirschmann can give no guarantee in respect of the correctness or accuracy of the information in this document Hirsc...

Page 3: ...10 100 Mbit s PoE port 20 1 5 3 Pin assignments 21 1 6 Display elements 21 1 7 Management interfaces 23 1 7 1 V 24 interface external management 23 1 8 FAULT signal contact 24 2 Installation 25 2 1 Checking the package contents 25 2 2 Wiring the connectors for supply voltage and signal contact 26 2 2 1 Devices featuring supply voltage with the characteristic value A 26 2 2 2 Devices featuring supp...

Page 4: ... OCTOPUS OS20 OS24 Managed Release 10 08 2017 2 7 Connecting data cables 32 3 Making basic settings 34 4 Monitoring the ambient air temperature 35 5 Maintenance and service 36 6 Technical data 37 A Further support 44 ...

Page 5: ...product only for the application cases described in the Hirschmann product information including this manual Operate the product only according to the technical specifications See Technical data on page 37 Connect to the product only components suitable for the requirements of the specific application case WARNING UNCONTROLLED MACHINE ACTIONS To avoid uncontrolled machine actions caused by data lo...

Page 6: ...tandards in safety technology Qualified personnel are aware of the dangers that exist in their work Qualified personnel are familiar with appropriate measures against these hazards in order to reduce the risk for themselves and others Qualified personnel receive training on a regular basis National and international safety regulations Verify that the electrical installation meets local or national...

Page 7: ... distance of 2 inches 5 cm from the device and at the specified relative humidity exclusively Install the device in a location where the climatic threshold values specified in the technical data are adhered to Make sure the environment does not heat the device Use the device in an environment with a maximum pollution degree that complies with the specifications in the technical data Relevant for u...

Page 8: ... Member States relating to the making available on the market of electrical equipment designed for use within certain voltage limits 2014 30 EU EMC Directive of the European Parlament and of the Council on the harmonisation of the laws of the Member States relating to electromagnetic compatibility In accordance with the above named EU directive s the EU conformity declaration will be at the dispos...

Page 9: ...ions These requirements are designed to provide sufficient protection against interference when the device is being used in a business environment The device creates and uses high frequencies and can also radiate these frequencies If it is not installed and used in accordance with this operating manual it can cause radio transmission interference The use of this device in a residential area can al...

Page 10: ...anual Redundancy Configuration user manual Reference manual for the graphical user interface Command Line Interface reference manual You find these manuals as PDF files on the Internet on the Hirschmann product pages www hirschmann com The Industrial HiVision Network Management software provides you with additional options for smooth configuration and monitoring ActiveX control for SCADA integrati...

Page 11: ...Installation OCTOPUS OS20 OS24 Managed Release 10 08 2017 11 Legend The symbols used in this manual have the following meanings Listing Work step Subheading ...

Page 12: ...rews There are convenient options for managing the device Administer your devices via a Web browser network management software e g Industrial HiVision a V 24 interface locally on the device The redundancy concept allows the network to be reconfigured quickly The devices provide you with a large range of functions which the manuals for the operating software inform you about You find these manuals...

Page 13: ...atalog www e catalog beldensolutions com on the web page of the device Item Product characteristic Product code Value for the characteristic 1 4 Product OS20 OCTOPUS device with Fast Ethernet ports without PoE ports OS24 OCTOPUS device with Fast Ethernet ports with PoE ports 5 hyphen 6 7 Number Special ports 00 0 PoE ports 08 8 PoE ports 8 9 Number 100 Mbit s ports 09 9 100 Mbit s ports 10 11 Numb...

Page 14: ...lue F on page 27 Voltage range DC incl maximum tolerances 16 8 V 60 V Connection type 7 8 connectors 5 pin N Rated voltage range DC 72 V 110 V Voltage range DC incl maximum tolerances 50 4 V 138 V Connection type 7 8 connectors 4 pin 18 Certifications E UL Railway along track Railway train F UL Railway along track Railway train Germanischer Lloyd E1 19 Software variant B Basic 20 Configuration H H...

Page 15: ...ge 2 RM Ring Manager FAULT Signal contact 2 100 Mbit s ports 3 Connecting the supply voltage 4 Grounding screw M3 5 V 24 connection for external management 6 Product code 7 LED display elements Port status 4 8 5 9 1 3 2 7 6 P1 P2 RM FAULT OS20 000900T5T5TAFBHH x y OCTOPUS OS20 Managed ETHERNET Switch Power V24 Function Pin 1 2 3 4 TX RX N C GND 3 4 1 2 V24 3 4 6 7 1 2 5 ...

Page 16: ...y voltage 4 Connection for the signal contact 5 Grounding screw M4 6 V 24 connection for external management 7 Product code 8 LED display elements Port status Power N C P 1 2 3 4 N C Pin Function P Power 1 2 4 3 FAULT 4 5 1 3 2 8 9 7 6 RM P x y OCTOPUS OS20 Managed ETHERNET Switch OS20 000900T5T5TNEBHH V24 Function Pin 1 2 3 4 TX RX N C GND 3 4 1 2 V24 Fault Power N C 1 2 3 4 5 N C N C Fault Fault...

Page 17: ...it s ports Ports 2 3 4 5 7 8 9 100 Mbit s PoE ports 3 Connecting the supply voltage 4 Connection for the signal contact 5 Grounding screw M4 6 V 24 connection for external management 7 Product code 8 LED display elements Port status P1 FAULT 4 5 1 3 2 8 9 7 6 RM P2 PoE PoE x y OCTOPUS OS24 Managed ETHERNET Switch OS24 080900T5T5TFFBHH V24 Function Pin 1 2 3 4 TX RX N C GND 3 4 1 2 V24 P Port 2 9 4...

Page 18: ...nnecting the supply voltage 4 Connection for the signal contact 5 Grounding screw M4 6 V 24 connection for external management 7 Product code 8 LED display elements Port status Power N C P 1 2 3 4 N C Pin Function P Power 1 2 4 3 FAULT 4 5 1 3 2 8 9 7 6 RM PoE PoE P x y OCTOPUS OS24 Managed ETHERNET Switch OS24 080900T5T5TNEBHH V24 Function Pin 1 2 3 4 TX RX N C GND 3 4 1 2 V24 N C 1 2 3 4 5 N C N...

Page 19: ...on page 28 1 5 Ethernet ports You can connect end devices and other segments to the device ports using twisted pair cables or optical fibers F O You find information on pin assignments for making patch cables here Pin assignments on page 21 1 5 1 10 100 Mbit s twisted pair port This port is designed as an 4 pin M12 socket The 10 100 Mbit s twisted pair port allows you to connect network components...

Page 20: ...e via the internal voltage supply The PoE voltage to the twisted pair cables is supplied via the wire pairs transmitting the signal phantom voltage The total PoE power output is limited to 61 6 W You can use the device management to configure and manage the total output of the device You will find more information in the Basic Configuration User Manual Pin Function 1 TD Transmission path 2 RD Rece...

Page 21: ...tive VPSE 2 RX Negative VPSE 3 TX Positive VPSE 4 RX Negative VPSE M12 8 pin X coded Pin 10 100 Mbit s 1000 Mbit s PoE 1 RX BI_DB Negative VPSE 2 RX BI_DB Negative VPSE 3 TX BI_DA Positive VPSE 4 TX BI_DA Positive VPSE 5 BI_DC 6 BI_DC 7 BI_DD 8 BI_DD LED Display Color Activity Meaning P P1 Supply voltage 1 Green Lights up Supply voltage is on None Supply voltage is too low P2 Supply voltage 2 Gree...

Page 22: ...d to the ring port Yellow Lights up The RM function is active The redundant port is enabled LED Display Color Activity Meaning 1 9 Link status None Device detects an invalid or missing link Green Lights up Device detects a valid link Flashes 1 time a period Port is switched to stand by Flashes 3 times a period Port is switched off Yellow Flashing Device is transmitting and or receiving data PoE Po...

Page 23: ...et housing is electrically connected to the housing of the device Applies to devices featuring supply voltage with the characteristic value A The V 24 interface is not electrically isolated from the supply voltage Figure 1 Pin assignment of the V 24 interface and the DE9 connector The Terminal cable is available as an accessory See Accessories on page 42 You will find a description of the V 24 int...

Page 24: ...the self diagnostic test Incorrect configuration of the HIPER ring The following condition is also reported in RM mode Ring redundancy reserve is available On delivery there is no ring redundancy monitoring Applies to devices featuring supply voltage with the characteristic value A Along with the supply voltage the signal contact is connected via a 5 pin M12 connector See Devices featuring supply ...

Page 25: ...eps to install and configure the device Checking the package contents Wiring the connectors for supply voltage and signal contact Installing and grounding the device Connecting the ferrite Connecting the supply voltage Operating the device Connecting data cables 2 1 Checking the package contents Check whether the package includes all items named in the section Scope of delivery on page 41 Check th...

Page 26: ...ontact are connected by means of a 5 pin M12 connector A coded e g ELWIKA 5012 PG7 from Hirschmann included in the delivery You find the prescribed tightening torque in General technical data section on page 37 WARNING ELECTRIC SHOCK The nominal voltage of 48 V specified for trains can temporarily exceed the SELV threshold of 60 V based on EN 50155 para 5 1 1 1 Use additional measures to limit the...

Page 27: ...5 mm to 1 0 mm AWG18 to AWG16 The supply voltage is connected via a 5 pin 7 8 connector See Accessories on page 42 You find the prescribed tightening torque in General technical data section on page 37 WARNING ELECTRIC SHOCK The nominal voltage of 48 V specified for trains can temporarily exceed the SELV threshold of 60 V based on EN 50155 para 5 1 1 1 Use additional measures to limit the surge vo...

Page 28: ... 2 3 Devices featuring supply voltage with the characteristic value N The input voltage is electrically isolated from the housing The supply voltage is connected via a 4 pin 7 8 connector See Accessories on page 42 You find the prescribed tightening torque in General technical data section on page 32 Use a power supply cable which is suitable for the voltage the current and the physical load Hirsc...

Page 29: ...f the OCTOPUS OS20 OS24 Managed device only use voltage supply cables with a diameter within the specified range Connect the supply voltage and signal lines 2 3 Installing and grounding the device Figure Pin Function 1 72 110 V DC 2 Not used 3 0 V 4 Not used Table 9 Pin assignment of the 4 pin 7 8 connector for connecting the supply voltage WARNING ELECTRIC SHOCK Applies to devices featuring suppl...

Page 30: ... ambient temperature to a maximum of 149 F 65 C You install the device on a 1 62 ft2 0 15 m2 metal plate to which you will connect no other heat sources Prepare the drill holes at the installation point Mount the device on a level surface with four M5 screws Seal all unused connections and ports with protection screws See Accessories on page 42 2 3 1 Grounding the device The device is grounded via...

Page 31: ...ue F and N Use the M4 screw for the protective ground Use toothed washers to ensure good electrical conductivity at the connection 2 4 Connecting the ferrite Applies to devices featuring supply voltage with the characteristic value F To adhere to EMC conformity you connect the ferrite supplied to the voltage input via the power supply cable Insert the power supply cable through the ferrite 3 times...

Page 32: ...h of the data cables as short as possible Use optical data cables for the data transmission between the buildings When using copper cables provide a sufficient separation between the power supply cables and the data cables Ideally install the cables in separate cable channels Verify that power supply cables and data cables do not run parallel over longer distances and that ideally they are install...

Page 33: ...Managed Release 10 08 2017 33 Proceed as follows Connect the data cables according to your requirements The tightening torque is 5 3 lb in 0 6 Nm Seal all unused connections and ports with protection screws See Accessories on page 42 ...

Page 34: ...manual Default settings IP address The device looks for the IP address using DHCP Password for management Login user password public read only Login admin password private read and write Parameters that can be set via the management are set to pre defined values in accordance with the MIB V 24 data rate 9600 Baud Ring redundancy deactivated Ethernet ports link status is not evaluated signal contac...

Page 35: ...cal data is a guideline that indicates to you that the maximum ambient air temperature has possibly been exceeded Therefore the temperature value displayed in the CLI and the GUI differs from the ambient air temperature To determine the actual permitted maximum value for operating the device you perform a reference measurement Install the device at the planned location Switch the device on and wai...

Page 36: ...e frequency of the switching operations Check the resistance of the closed relay contacts and the switching function depending on the frequency of the switching operations Hirschmann is continually working on improving and developing their software Check regularly whether there is an updated version of the software that provides you with additional benefits You find information and software downlo...

Page 37: ... V DC 60 V DC Connection type M12 connector 5 pin Tightening torque 5 3 lb in 0 6 Nm Power loss buffer 10 ms Overload current protection at input Non replaceable fuse Back up fuse Nominal rating Characteristic 2 A slow blow Peak inrush current 14 A Power supply Type F Redundant power supply Rated voltage range DC 24 V 48 V Observe the warning for railway standard EN 50155 See Devices featuring sup...

Page 38: ... m maximum 1060 hPa 1312 ft 400 m Climatic conditions during storage Ambient temperature 40 F 185 F 40 C 85 C Humidity 5 100 also in condensing atmospheres c Air pressure minimum 700 hPa 9842 ft 3000 m maximum 1060 hPa 1312 ft 400 m Degree of protection IP65 67d Mounting Flat surface mounting Screw type M5 Pollution degree 2 a Applies to devices with PoE only as long as the temperature of the devi...

Page 39: ...tic field 80 MHz 2700 MHz 20 V m IEC EN 61000 4 4 Fast transients burst AC DC supply connection Data line 2 kV 4 kV IEC EN 61000 4 5 Voltage surges DC supply connection Data line line line line ground 1 kV 2 kV 1 kV IEC EN 61000 4 6 Conducted disturbances 150 kHz 80 MHz 10 V EN 61000 4 9 Pulse magnetic fields 300 A m EMC interference emission EN 55032 Class A Yes 52 8 mm 2 08 inch 171 8 mm 6 77 in...

Page 40: ...ype Tests Part 1 Yes IEC 60870 2 2 table 3 normal installation according to EN 61850 3 Yes EN 61373 Category 1 Class A broadband noise installation in acc with EN 50155 Yes Shock IEC 60068 2 27 Test Ea test level according to IEC 61131 2 Yes IEC 60870 2 2 table 3 normal installation according to EN 61850 3 Yes EN 61373 Category 1 Class A broadband noise installation in acc with EN 50155 Yes 10 100...

Page 41: ...vice Connector ELWIKA 5012 PG7 for supply voltage and signal contact Note The connector ELWIKA 5012 PG7 933 175 100 supports a temperature range from 13 F to 158 F 25 C to 70 C It may thus limit the application range of the overall system Special connectors with protection classes IP65 67 and an extended temperature range are available on request General safety instructions OS24 080900T5T5TFFBHH O...

Page 42: ...001 Connector ELWIKA 5012 PG7 5 pin M12 socket for supply voltage and signal contact 933 175 100 AutoConfiguration Adapter ACA11 M12 943 972 001 Field attachable 5 pin M12 socket A coded with 2 cable outputs RKC5 Duo M12 connector 4 pin D coded 934 445 001 7 8 connectors 4 pin 942 086 004 7 8 connectors 5 pin 942 086 005 Connection cable with M12 connector D coded 934 497 00x Transition M12 D code...

Page 43: ...unity for signal and telecommunication systems EN 50155 Railway applications Electronic equipment used on rolling stock EN 55032 Electromagnetic compatibility of multimedia equipment Emission Requirements EN 61000 6 2 Electromagnetic compatibility EMC Part 6 2 Generic standards Immunity for industrial environments EN 61131 2 Programmable controllers Part 2 Equipment requirements and tests FCC 47 C...

Page 44: ...Hirschmann Competence Center is ahead of its competitors on three counts with its complete range of innovative services Consulting incorporates comprehensive technical advice from system evaluation through network planning to project planning Training offers you an introduction to the basics product briefing and user training with certification You find the training courses on technology and produ...

Page 45: ...Installation OCTOPUS OS20 OS24 Managed Release 10 08 2017 45 ...

Page 46: ......

Reviews: